GC Columns

A GC column is a piece of apparatus found inside gas chromatography systems through which a gas sample is passed and separated into its constituent components so they can be measured by a detector as they leave the column. Available as either packed or capillary columns, capillary columns having a higher separation efficiency but greater susceptibility to overload than packed columns.

GC Columns Provider Reviews are provided below. If you would like assistance in obtaining a quotation we provide a free "Get Quote" email forwarding service and will direct your enquiry to the relevant provider/supplier requesting that they contact you directly. We provide this as a free service to site visitors in accordance with site terms and conditions. Please note that any commercial transactions that may subsequently take place are strictly between the supplier/provider and the site visitor, the operators of News-Medical.net are not a party to any transaction and do not endorse any of the products or services or provide any representations or warranties that they are suitable to the personal circumstances of any individual site visitor.

To promote your Products or Services in the News-Medical.Net Directory please email

If you'd like us to help you source a Quotation for GC Columns please click here. Once submitted, we will try and place you in contact with a suitable GC Columns supplier within 48 hours.
Medical Devices
Our easy to handle DB-ProSteel metal columns are deactivated with a new formula (this is not glass lined steel) to provide inertness which truly rivals fused silica. DB-ProSteel metal columns can be custom wound upon request for small GC ovens.
Polycyclic aromatic hydrocarbons (PAHs) are chemical compounds consisting of fused aromatic rings formed during the incomplete combustion of organic materials. The European Commission (EU) recommends the monitoring of 16 PAHs possessing both genotoxic and carcinogenic properties.
Agilent J&W DB-2887 columns are specifically designed for simulated distillation of ASTM Method D2887. With rapid conditioning, fast run times and low bleed characteristics, Agilent's bonded and cross-linked DB-2887 columns deliver high levels of performance in GC applications.
Agilent J&W DB-1ms Ultra Inert delivers consistent column inertness performance to ensure sensitivity, performance, and integrity. With excellent peak shapes, exceptionally low bleed and high signal-to-noise ratios, DB-1ms Ultra Inert performs effectively with even the most challenging active analytes. DB-1ms is also individually tested with Ultra Inert 1ms test probe mixture for peace of mind.
DB-35ms columns are precision-engineered by Agilent to deliver excellent performance in a range of GC applications, particularly in confirmational analyses. The midpolarity columns operate over an extended temperature range up to 340/360 °C.
The DB-17 GC Column is a (50%-Phenyl)- methylpolysiloxane column of mid polarity. The DB-17 GC Column is excellent for confirmation analysis. The DB-17 GC Column is equivalent to USP Phase G3. Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand.
Biofuels are becoming more attractive as a viable supplement or alternative to petroleum-based fuels. Agilent J&W Biodiesel is designed and application-optimized for the analysis of biodiesel to meet ASTM and CEN testing standards.
The DB-1301 GC column is a (6%-Cyanopropyl-phenyl)-methylpolysiloxane column. The DB-1301 is the equivalent to USP Phase G43. The DB-1301 is a low- to mid- polarity column.
Agilent J&W DB-UI 8270D GC columns deliver excellent peak shape performance for active semi-volatile organic compounds targeted by EPA Method 8270D, so you can perform environmental trace-level analysis with the utmost confidence.
Simplify your operations with Agilent J&W DB-CLP1 and DB-CLP2 GC columns – the most flexible universal column pair for nine EPA dual- ECD pesticide methods. Together these fast, reliable columns deliver excellent resolving power with exceptionally low bleed while eliminating the need for time-consuming column switching.
When performing trace level analysis on very active compounds, Agilent Inert Flow Path solutions ensure a reliably inert flow path for higher sensitivity, accuracy and reproducibility.
Agilent manufactures non-polar DB-5.625 bonded columns that are specially processed to exhibit excellent inertness for EPA Semivolatile Methods 625, 1625, 8270, and CLP protocols.
Agilent J&W DB-5ms Ultra Inert delivers industry-leading analytical performance in a range of chromatographic applications. DB-5ms Ultra Inert is low bleed and features excellent signal-to-noise ratio and peak shapes, enabling high levels of performance in analyzing challenging active analytes.
Agilent J&W Packed GC Columns are designed and manufactured to offer excellent and reproducible performance for all sample types associated with packed column separations, most important in the hydrocarbon processing industry.
Agilent J&W Scientific GC columns offer the highest quality and performance of any GC columns on the market today. From the lowest bleed levels and the best inertness for acid, base, and mixed functional compounds, to the tightest column-to-column reproducibility, Agilent GC columns deliver superior reproducible performance for benign to the most difficult types of samples.
The Thermo Scientific C2V-200 Gas Chromatograph is based on proprietary micro GC technology and is an excellent tool for productivity and confidence in lab or on-line gas analysis.
Agilent's high resolution DB-17ht columns provide excellent performance criteria for accurate confirmational analyses. The midpolarity columns are solvent rinsable and feature polyimide-coated fused silica tubing.
Agilent J&W DB-35ms Ultra Inert is a mid-polar column, for applications where different selectivity is needed for enhanced separations, including pesticide analysis and drugs of abuse testing.
This leading-edge column technology is ideal for applications that require faster run times, such as high-throughput screening, fast process monitoring, and fast method development. In fact, Agilent High Efficiency GC columns can reduce your sample run time by 50% or more without compromising resolution.