Webinar Overview: Using Stop-Flow Techniques NMR and IR, to Optimize Reaction Conditions

© SUWIT NGAOKAEW/Shutterstock.com

In order to control, optimize, and analyze organic chemical reactions, it is vital to gain a mechanistic understanding of how they occur. It can be hard to study reaction kinetics, however, when the rate of reaction is extremely fast. This presents an obstacle to this understanding.

Guy Lloyd-Jones, the Professor of Organic Chemistry at Forbes, gave a webinar in which he presented some new, exciting techniques he had develop with his colleagues in order to overcome this issue. He described how these techniques can be applied to simple, regular laboratory instruments.

Professor Lloyd-Jones began his webinar by outlining the meaning of “fast” in this context, explaining why fast reactions can be hard to monitor. Fast reactions present problems in the following areas: fully initiating the reaction; temperature control during the initiation of the reaction and the reaction itself; and precisely assembling the reaction with the correct stoichiometries and component volumes. Furthermore, the reaction needs to be homogenous, which is difficult in the case of NMR-based experiments in which a long, thin reaction vessel is used.

As an example, Professor Lloyd-Jones outlined the lack of homogeneity and poor mixing which can occur using the protodeboronation of difluorinated boronic acid. He showed how complete homogenous mixing has not taken place, as indicated by the NMR spectra generated.

Stop-Flow Technique

Focusing on the classic stop-flow (SF) technique, he outlined the methods which can be used for in situ analysis. Along with TgK and Bruker four years previously, Professor Lloyd-Jones adapted this technique in order to provide an efficient, variable ratio multi-mixing system which saves both money and time. As well as introducing Bruker’s InsightXpress stop-flow solution, Professor Lloyd-Jones explained how it is possible to interface the system with NMR and infra-red (IR) spectrometers.

With the classic SF technique, component A meets component B before they react while passing down a tube. Once the flow has stopped, the reaction is analyzed at a particular point along the tube. Outlining this method’s advantages and limitations, Professor Lloyd-Jones gave a schematic overview of the SF set up and process.

Benefits of SF Technique

Benefits of this method include the ability to obtain kinetics data which is highly reproducible; the ability to purge all contaminants out; and the useful communication between the spectrometer, SF device, and the computer used to monitor the process.

Professor Lloyd-Jones then adumbrated how the reaction was performed four times in order to obtain four kinetic datasets, and how different sets of kinetics can be generated by altering the concentration of individual components in the reaction. Using the different rates, a graph can then be generated which shows the way the system responds to the concentration of this component and the kinetic dependents on it.

Even though this is very useful information, Professor Lloyd-Jones explained that three stock solutions of the individual component need to be made up in order to obtain these three data sets. Even though the SF technique is quick and very reproducible, valuable time and materials must be used as it is labor intensive to vary the component concentration and each solution must be washed out completely.

Consequently, Professor Lloyd-Jones described the new system he, Bruker, and TgK had created four years earlier. They developed a variable ratio multi-mixing system in which at least three inputs, which are independently driven, are used. This allows for the generation of different outputs, different reaction mixtures, and the possibility of keeping one component constant, if necessary.

Following this, the professor discussed this new system in the context of NMR and IR studies.

In relation to IR, he outlined the CF3 transfer’s kinetics, as well as the advantages of pairing multi-mixing with an attenuated total reflectance (ATR) set-up. Furthermore, the professor offered an example of using MX-SF-ATR Fourier transform infrared spectroscopy to deliver an analysis of a fast and air-sensitive reaction which is both time- and reagent-efficient.

Professor Lloyd-Jones described some of the issues inherent in NMR-based experiments, such as the lack of reproducibility, inefficient mixing, and poor temperature control. He then continued to explain how the multi-mixing SF solution can address these issues.

The professor illustrated how it is possible to use the technique for a protodeboronation reaction using Bruker’s InsightXpress SF solution. He then has a schematic overview of this reaction. He also explained the technique’s benefits, such as high reproducibility, sample efficiency, simple cleaning, high quality data density, and precise and variable temperature control.

About Bruker BioSpin - NMR, EPR and Imaging

Bruker BioSpin offers the world's most comprehensive range of NMR and EPR spectroscopy and preclinical research tools. Bruker BioSpin develops, manufactures and supplies technology to research establishments, commercial enterprises and multi-national corporations across countless industries and fields of expertise.


Sponsored Content Policy: News-Medical.net publishes articles and related content that may be derived from sources where we have existing commercial relationships, provided such content adds value to the core editorial ethos of News-Medical.Net which is to educate and inform site visitors interested in medical research, science, medical devices and treatments.

Last updated: Mar 11, 2022 at 12:28 AM

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Bruker BioSpin - NMR, EPR and Imaging. (2022, March 11). Webinar Overview: Using Stop-Flow Techniques NMR and IR, to Optimize Reaction Conditions. News-Medical. Retrieved on April 19, 2024 from https://www.news-medical.net/whitepaper/20190107/Webinar-Overview-Using-Stop-Flow-Techniques-NMR-and-IR-to-Optimize-Reaction-Conditions.aspx.

  • MLA

    Bruker BioSpin - NMR, EPR and Imaging. "Webinar Overview: Using Stop-Flow Techniques NMR and IR, to Optimize Reaction Conditions". News-Medical. 19 April 2024. <https://www.news-medical.net/whitepaper/20190107/Webinar-Overview-Using-Stop-Flow-Techniques-NMR-and-IR-to-Optimize-Reaction-Conditions.aspx>.

  • Chicago

    Bruker BioSpin - NMR, EPR and Imaging. "Webinar Overview: Using Stop-Flow Techniques NMR and IR, to Optimize Reaction Conditions". News-Medical. https://www.news-medical.net/whitepaper/20190107/Webinar-Overview-Using-Stop-Flow-Techniques-NMR-and-IR-to-Optimize-Reaction-Conditions.aspx. (accessed April 19, 2024).

  • Harvard

    Bruker BioSpin - NMR, EPR and Imaging. 2022. Webinar Overview: Using Stop-Flow Techniques NMR and IR, to Optimize Reaction Conditions. News-Medical, viewed 19 April 2024, https://www.news-medical.net/whitepaper/20190107/Webinar-Overview-Using-Stop-Flow-Techniques-NMR-and-IR-to-Optimize-Reaction-Conditions.aspx.

Other White Papers by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.