Gas Chromatograph TT-GC9000 from Torontech

Gas chromatography carries out the quantitative analysis and peculiar smell testing for residual solvent on food packaging cases after printing. It also tests the pureness and quality of organic solvents.

Working Principle:

Sample of gas, liquid or solid is processed and passes through vaporizing chamber, brought to chromatographic column separation system. Carried by nitrogen, the sample mixture passes and contacts the chromatographic column, and the composition components of the mixture are separated by chromatographic column. Then every separated component is brought to the detector system, and transformed by the detector to equivalent electronic signal, which is collected and recorded as data, so as to make qualitative and quantitative analysis of the components of the sample mixture.

Features:

  • Best quality/price ratio
  • Integrated design, easy to install and maintain
  • Chromatogram data work station connection capability
  • FID detector
  • Wide column box (300×300×200mm)
  • Low noise function
  • Rapid vaporizing and column sample injection modes
  • CO and CO2 microanalysis with integrating optional reforming furnace.
  • Microchip controlled temperature rise
  • Built-in computer, user interface displays data of various temperatures
  • Column box temperature control +10 °C - 400 °C,
  • Eight-step temperature rise
  • Temperature increase speed: 0 - 30 °C/min,  (increase 0.1 °C/min)
  • Eight A type control points
  • Overheat protection function

Technical Specifications:

Hydrogen Flame Ionization Detector (FID):

  • Sensitivity: Mt≤1×10-11 g/s (palmityl)
  • Shift: ≤0.02 mv/h
  • Temperature Range: Room temperature+10℃ ~ 400 °C
  • Temperature Accuracy: ≤0.1 °C
  • Temperature Speed: 0.1~40 °C/min

 

Thermal Conductivity Detector

(TCD)

Hydrogen Flame Ionization Detector

(FID)

Electronic Capture Detector

(ECD)

Flame-Photometric Detector

(FPD)

Nitrogen and Phosphorous Detector (NPD)

Sensitivity

S≥2500mv.ml/mg (benzene), baseline shift

≤60 μV /0.5h

M≤1×10-11    g/sec (Palmityl), baseline shift

≤1 x 10-12 A/0.5h

M≤2×10-13 g/ml (r-666)

Ms≤5×10-11g/sec (Thiophene)

Mp≤1×10-11 g/sec

(ethyl-1605)

Mn:1×10-13 g/sec

Mp:1×10-13 g/sec

(ethyl-1605)

Noise

≤10μV

≤1×10-13 A

-

-

-

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.