CLINITEK Status® Connect System from Siemens Healthineers streamlines wireless or wired connectivity and testing oversight in point-of-care urinalysis for enhanced risk management.

  • Provides adaptable connectivity solutions and enhances POC testing workflow efficiencies by incorporating data directly to the LIS, EMR, or via point-of-care data management software solutions
  • Enhanced barcode response time enables rapid entry of lot and expiration data with a single scan
  • Advanced operator control functions improve risk management and prevent unauthorized use
  • Steers compliance across testing sites with programmable QC protocols and QC lockout
  • Auto-Checks* help to guarantee the quality and precision of data while facilitating an enhanced interpretation of results

Features and benefits

With the CLINITEK Status Connect System, users can gain control of their point-of-care urinalysis testing program.

Supports flexible and efficient connectivity

  • Users can connect through wireless, Ethernet, or serial transmission
  • Connect to the hospital’s LIS/HIS, EMR, or point-of-care middleware solution
  • Supports HL7 and POCT1-A2 protocols
  • Interfaces with leading point-of-care data management solutions for centralized control and testing oversight—including POCcelerator® Data Management System; RAPIDComm® Data Management System; MAS RALS®-Plus; TELCOR Quick-Linc®

Advanced operational control and management

  • Offers customized operator access level
  • Assists operator ID entry and lockout
  • Prevents unauthorized use, depending on customizable settings

Enhanced quality control

  • Define specific QC protocols for operators across various sites
  • Optional barcode reader negates manual steps and decreases transcription errors
  • QC lockout if the protocol is not followed or the QC test fails
  • Sustain up-to-date operator certification records and regulate operator access as needed
  • On-demand availability of QC documentation and report downloads
  • Store up to 200 QC test records

Improved data integrity

Auto-Checks

  • Verifies each strip for humidity to prevent reporting of falsely elevated results
  • Identifies interferences in test samples and offers printed notation for enhanced results interpretation
  • Recognizes Siemens Healthineers strip type to save time

Assays

The CLINITEK Status Connect System offers an automated reading of the Multistix® family of urinalysis tests:

  • Leukocyte
  • Protein
  • Nitrite
  • Blood
  • Ketone
  • Glucose
  • Bilirubin
  • pH
  • Urobilinogen
  • Specific Gravity
  • Creatinine
  • Albumin-to-Creatinine Ratio (ACR)
  • Protein-to-Creatinine Ratio
  • Albumin
  • CLINITEST® hCG Pregnancy Test

Technical specifications

Source: Siemens Healthineers

Semi-quantitative Tests Measured
Routine urine tests albumin, bilirubin, creatinine, glucose, ketone, leukocytes, nitrite, pH, protein, specific gravity and urobilinogen
Kidney disease test albumin-to-creatinine ratio
Pregnancy test Human Chorionic Gonadotropin (hCG)
General Specifications
Depth 10.7 in. or 27.2 cm
Width 6.7 in. or 17.1 cm
Height 7.5 in. or 18.5 cm
Weight 5.0 lbs or 2.3 kg
Electrical rating 100V - 240V AC, 50-60 Hz (with in-line lead)
Battery operation Not available
Ambient temperature range 18 to 30 ºC (64 to 86 ºF)
Humidity range 18-80% relative humidity, non-condensing
Compliance UL, CE, EMC
Calibration automatic, self-calibrating
Communication Capabilities
Communication protocol HL7, POCT1-A2
Data transmission options wireless, Ethernet or serial connection
Interfaces with leading point-of-care data management solutions*
  • POCcelerator® Data Management System
  • RAPIDComm® Data Management System
  • MAS RALS®-Plus
  • Telcor Quick-Linc®
Memory
Patient test results 700
QC test results 200
Operator IDs 700
Quality Control Management Features
QC testing and reporting  
QC reminders or mandatory prompt  
QC lockout  
Barcode Data Entry
Patient ID, operator ID and name,
QC control type, lot number, strip lot/expiration, and hCG lot/expiration
 
Barcode Symbology Supported
Code 93, Code 39 (with and without check digit), Code 128, Coda Bar, Interleaved 2 of 5 (with and without check digit)  
Operator Security Features
Define up to 700 operators  
Operator lock-out to prevent unauthorized use  
Customize access level for each operator for the following functions:
  • Performing patient tests
  • Performing QC tests
  • Recalling results
  • Modifying system settings
 

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.