Drentech Emotrans Chest Drainage System from Redax

A stable, solid design for the most compact device in chest drainage blood recovery application.Drainage controls vacuum via water column regulation. Emotrans water valve chest drain has been engineered to utilize an advanced integral filter placed inside collection chamber. A large filter screens blood clots through the 200 micron mesh membrane. Only system available with built in double filtration: macro aggregates filter inside chamber and micro-aggregates one built in the blood bag, ATS Chest Drain allows recovery of blood into the collection chamber, based on needs dictated by clinical requirements. This flexibility does not require us of blood bag each time, aiding in containing operating costs. Emotrans is developed with a unique Auto Regulation system that maintains proper flow rate at all times. It allows fro proper bubbling regulation, independent from vacuum and flow. Redax Chest Drain is practical to use and frees staff from monitoring and manging the vacuum source. It has solid built in handle, Emotrans can be fixed to patient bed, allowing for easy transportation and patient movement. Device suitable for use in Cardiac Surgery and Emergency, as an efficient device for collection of blood and autologous autotransfusion.

Features:

  • double stage filtration by means of 200 micron inside collection chamber and 40 micron built into blood bag
  • high quality of collected blood guaranteed by double filtration and by mean of a seal-valve protecting from possible contamination
  • patented water manometer allowing vacuum tuning from -5 to -25 cmH2O
  • underwater seal chamber for easy air leak bubbling detection and precise intra-pleural patient's pressure
  • new compact size improves stability and helps save space
  • large capacity for 2.200 ml exudate collection with graduated scale chamber
  • self sealing cap for fresh diagnostic sample on inlet port
  • auto-regulation feature limits staff involvement in chest drain management
  • available a special configuration to interface Cell-Saver equipment
  • 100% latex and PVC Free

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.