ß-Hydroxybutyrate LiquiColor® reagent system to detect ketosis

Stanbio Laboratory, an EKF Diagnostics company, has developed the ß-Hydroxybutyrate LiquiColor® Reagent System to improve the detection of clinically significant ketosis.

ß-Hydroxybutyrate LiquiColor® reagent system

Image credit: EKF Diagnostics

Ketosis is elevated levels of ketones in the body that occur when stored fats are broken down in response to a low supply of energy (glucose). Using the reagent system, levels of the ketone ß-Hydroxybutyrate in serum and plasma can be used to clinically diagnose and monitor diabetes mellitus, alcoholism, glycogen storage disease, high fat/low carbohydrate diets, pregnancy, alkalosis, ingestion of isopropyl alcohol, and salicylate poisoning.

As ß-Hydroxybutyrate is the main ketone produced during ketosis (~78%), the blood assay provides a better tool than the nitroprusside test strips commonly used for the detection of ketone bodies in urine, which only detect 22% of ketones present. ß-Hydroxybutyrate also demonstrates excellent stability, making it the most reliable indicator of clinically relevant ketosis and ketoacidosis.

The ß-Hydroxybutyrate LiquiColor® Reagent System produces quantitative and objective results and provides an excellent tool for differentiating metabolic acidosis and monitoring therapy. Its precise and sensitive quantitative results enable earlier detection of ketosis and faster patient treatment, thus improving Emergency Room (ER) and Critical Decision Unit (CDU) throughput and efficiency.

ß-Hydroxybutyrate is used by many of the most respected healthcare systems in the United States. The diagnostic effectiveness of Stanbio’s enzymatic Beta-Hydroxybutyrate (ß-HB) LiquiColor® assay is rapidly driving its acceptance in hospital laboratories across the USA as the new standard of care in ketosis testing. Over 850 (representing 20%) of US hospitals are now using the assay for accurate, specific and quantitative testing of this main ketone produced during ketosis. Consequently, physicians can make better informed clinical decisions which are changing the way hospitals manage patients displaying symptoms of ketoacidosis.

The liquid-stable LiquiColor ß-HB reagent can be used on open channel chemistry analysers from twenty different manufacturers. A point-of-care option is also available in the form of the STAT-Site® M ß-HB strip-based testing system.

Controls and linearity standards are available and all reagents have a 24-month shelf life from date of manufacture.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    EKF Diagnostics. (2020, May 12). ß-Hydroxybutyrate LiquiColor® reagent system to detect ketosis. News-Medical. Retrieved on April 24, 2024 from https://www.news-medical.net/news/20160107/c39f-Hydroxybutyrate-LiquiColor-reagent-system-to-detect-ketosis.aspx.

  • MLA

    EKF Diagnostics. "ß-Hydroxybutyrate LiquiColor® reagent system to detect ketosis". News-Medical. 24 April 2024. <https://www.news-medical.net/news/20160107/c39f-Hydroxybutyrate-LiquiColor-reagent-system-to-detect-ketosis.aspx>.

  • Chicago

    EKF Diagnostics. "ß-Hydroxybutyrate LiquiColor® reagent system to detect ketosis". News-Medical. https://www.news-medical.net/news/20160107/c39f-Hydroxybutyrate-LiquiColor-reagent-system-to-detect-ketosis.aspx. (accessed April 24, 2024).

  • Harvard

    EKF Diagnostics. 2020. ß-Hydroxybutyrate LiquiColor® reagent system to detect ketosis. News-Medical, viewed 24 April 2024, https://www.news-medical.net/news/20160107/c39f-Hydroxybutyrate-LiquiColor-reagent-system-to-detect-ketosis.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
EKF Diagnostics to exhibit new STAT-Site WB β-ketone and glucose handheld analyzer at Medica 2021