The Allegra 6 Benchtop Centrifuge from Beckman Coulter is a general purpose, high performance equipment that provides excellent quality and reproducibility, and delivers reliable performance.

  • Designed for high-volume labs
  • 3.0 L max capacity
  • 6,100 RPM
  • 5,710 x g
  • 1-3 Liter
  • Available in refrigerated/ambient benchtop options and refrigerated knee-well models

Features

Ideal for cell culture, plasma and other general-purpose separations

  • Process up to 56 x 15 mL conical tubes or 12 standard microplates
  • Spin tubes, bottles, microplates and specialty bottles up to 3,210 x g
  • Interchangeable rotors available
  • Offered in refrigerated or ambient benchtop options as well as refrigerated kneewellTM models

GH-3.8 Rotor

  • High-capacity (4 x 750 mL)
  • Sping up to 3,750 rpm (3,210 x g)

Modular Disk Adapters for the GH-3.8 Rotor

  • Accommodate a wide variety of tubes

MicroPlus carriers for GH-3.8 rotors

  • Perfect for cell adhesion assays and high-throughput screening
  • Accommodates 12 standard microplates or four deep-well microplates
  • Spin up to 3,250 rpm (1,924 x g)

Aerosolve canisters for GH-3.8 rotors

  • Exclusive design helps minimize contamination from broken or leaking tubes
  • Autoclavable up to 121 °C
  • Canisters seal with an O-ring

GA-6 Fixed Angle Rotor

  • Spin tubes and bottles from 1.5 mL to 250 mL at up to 5,710 x g
  • Aerosol-tight lid to minimize contamination from broken or leaking tubes

Instrument Specifications

Allegra 6 Centrifuge System Specifications

UNSPSC

41103903

Height

394 mm (15.5")

Width

546 mm (21.5")

Depth

660 mm (26")

Weight

51.7 kg (114.0 lbs)

Approximate acceleration time

1 min

Approximate deceleration time

3 min

Drive type

Direct drive, replaceable brushes

g Force

5,710

Maximum speed

6,100 rpm

Maximum heat dissipation into room (steady-state)

0.9 kW (3,701 Btu/hr)

Noise level 1 M in front of centrifuge

< 60 dBA

Set temperature

N/A

Set time

30 min timer, hold

Speed control

± 30 rpm of set speed

Nominal cap

4 x 750 mL

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.