I8M-15 incinerator is our smallest incinerator specially designed for medical waste. This model is a controlled air incinerator, providing optimal combustion conditions for different waste types. The top loading design provides liquid retention making this incinerator ideal for incineration of many different waste types. This unit benefits from a secondary chamber with afterburner for the re-burn of harmful emissions with a 0.5 second retention time.
Emission Data
Average emissions / EU standards On basic incinerators (with secondary chamber)
Parameter |
Limits
(1/2 hr av) |
Measured |
Total dust |
30 mg/m3 |
12 mg/m3 |
Sulphur dioxide |
200 mg/m3 |
2,4 mg/m3 |
Nitrogen dioxide* |
400 mg/m3 |
60 mg/m3 |
Carbon monoxide |
100 mg/m3 |
78,3 mg/m3 |
Technical Specifications
Operational Specifications |
Combustion Chamber Volume (m3) |
0.13 m3 |
Burn Rate* |
up to 20 kg per hour |
Average Fuel Consumption |
4 - 5 ltrs p/h |
Operational Temperature |
> 850 °C |
Gas Retention in Secondary Chamber |
2 secs |
Temperature Monitoring |
Yes |
Average ash residue (%) |
3% |
Thermostatic Device |
Yes |
Physical Specifications |
External Length (mm) |
750 mm |
External Width (mm) |
750 mm |
External Height (mm) |
2720 mm |
Door Size (m) |
0.50 x 0.39 |
Shipping Weight |
652 kg |
For reference only, not to be used for installation purposes. * All burn rates are dependant on the calorific value of the waste being incinerate. Atmospheric conditions,fuel (gas/oil) quality, additonal accessories (autoloader, de-asher) can also have a major impact on actual burn rates.
*Subject to calorific value of waste stream. For reference only, not to be used for installation purposes.