Modelling Defibrillation

NewsGuard 100/100 Score

Cardiac fibrillation describes the deterioration of the heart’s electrical activity, which drives the heart’s periodic pumping. This electrical activity, which is usually organized, becomes disorganized into self-sustained patterns of electrical activation.

Cardiac fibrillation leads to a reduction in cardiac output that can quickly cause death in the absence of clinical intervention. Cardiac defibrillation, which relies upon the use of an implantable and automatic device, delivers a strong electric shock to the heart. Cardiac defibrillation is the only effective technique for treating life-threatening disturbances in cardiac rhythm.

Image Credit: Racha Phuangpoo / Shutterstock.com

3D models

Accurate three-dimensional (3D) models of ventricular defibrillation, along with close experimental observation, have been key to uncovering the electrical events that occur as a result of the interaction between a fibrillating myocardium and the administration of electrical shock.

The effectiveness of a cardiac defibrillator depends on the positioning of the electrodes that transmit the electrical currents to the heart. Most implanted defibrillators are used to treat people aged 80 years or over, but they may also be used to treat children. The positioning of a defibrillator is particularly important when children are involved, as their growth may gradually change the positioning. The anatomy of the child’s heart also differs from that of the adult heart.

Software models

Software modeling systems now exist to determine the optimal positioning of defibrillators. Modeling systems can be used to map the thorax and indicate the prime positioning of either internal or external cardiac defibrillators, thereby increasing their efficacy.

This software uses surgical planning applications, along with myocardial voltage gradients, to predict the likelihood of the defibrillator being successful. If the critical mass hypothesis is applied, effective defibrillation is only achieved if a threshold voltage gradient is produced in a large proportion of the heart muscles.

Specifically, a gradient of 3 to 5 volts per centimeter in 95% of the heart is usually necessary. Gradients over 60 volts per centimeter can damage heart tissue. The software is designed to obtain safe gradient values that are still above the threshold for successful defibrillation.

Simulation studies using this software have shown that even small changes in the positioning of electrodes may have significant effects on defibrillation. The modeling software systems provide guidance in choosing the optimal placement of defibrillators in children and adults.

Bidomain modeling

Recent designs are based on bidomain models of cardiac tissue. Biodomain models provide a realistic heart shape and geometry of heart fibers for determining how cardiac tissue responds to electric shock.

In one study using the bidomain model of the myocardium, which accounts for the flow of electrical current in both interstitial and intracellular domains, Sepulveda et al., showed membrane polarization induced by shock may be more complex than was previously thought.

Their simulation study indicated that the myocardium tissue response to a strong unipolar stimulus involved depolarizing and hyperpolarizing effects that occur in close proximity if both the intracellular and extracellular spaces are anisotropic or directionally dependent but to a different degree. In monodomain models, equal anisotropies are inherently assumed and it is not possible for polarization of opposite polarity to occur.

The possibility of these “virtual electrodes” existing was later followed up using optical mapping, which confirmed the prediction. Virtual electrode polarization (VEP) has since become a mainstay in defibrillation research. VEP in the myocardium now refers to the areas of electric shock-induced membrane depolarization and hyperpolarization and their spatial pattern in the ventricles, which represents the new myocardial state at the end of the shock. The post-shock electrical activity that follows is largely dependent on this new state of the myocardium.

Bidomain modeling studies have shown that the post-shock VEP pattern is the main factor for determining the origin of post-electric shock activations in the second stage of the defibrillation process. In regions where electric-shock-induced virtual anodes and cathodes are in close proximity, it is possible to elicit a “break” excitation after the shock has ended.

Depolarized cells in the cathode provide an excitatory current that induces a regenerative depolarization and propagating wave in the newly created virtual anodes within immediate proximity. Positive VEP can also result in straightforward depolarization of the excitable gaps present when the shock is delivered to the fibrillating myocardium.

These are referred to as “make” excitations and their discovery, along with that of break excitations, has led to an improved understanding of how new activations develop as a result of administering a strong stimulus.

References

  1. https://www.cchaforlife.org/
  2. https://www.who.int/
  3. www.heart.org/
  4. https://www.resus.org.uk/
  5. http://europace.oxfordjournals.org/content/16/5/705

Further Reading

Last Updated: Jan 13, 2023

Sally Robertson

Written by

Sally Robertson

Sally first developed an interest in medical communications when she took on the role of Journal Development Editor for BioMed Central (BMC), after having graduated with a degree in biomedical science from Greenwich University.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Robertson, Sally. (2023, January 13). Modelling Defibrillation. News-Medical. Retrieved on April 23, 2024 from https://www.news-medical.net/health/Modelling-Defibrillation.aspx.

  • MLA

    Robertson, Sally. "Modelling Defibrillation". News-Medical. 23 April 2024. <https://www.news-medical.net/health/Modelling-Defibrillation.aspx>.

  • Chicago

    Robertson, Sally. "Modelling Defibrillation". News-Medical. https://www.news-medical.net/health/Modelling-Defibrillation.aspx. (accessed April 23, 2024).

  • Harvard

    Robertson, Sally. 2023. Modelling Defibrillation. News-Medical, viewed 23 April 2024, https://www.news-medical.net/health/Modelling-Defibrillation.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
New cryoablation technique eliminates ventricular tachycardia in 94% of patients