Using Dynamic Light Scattering (DLS) for Liposome Size Analysis

NewsGuard 100/100 Score

Dynamic light scattering (DLS) is a technique that is used to measure the size of particles, generally particles that are in the sub-micron region. The technique is also referred to as photon correlation spectroscopy and quasi-elastic light scattering.

Applications

The technique can be used to determine the size of liposomes, spherical bilayer vesicles that may be naturally derived or synthesized from man-made substances. Liposomes are mainly used in the biopharmaceutical industry as carriers for drug delivery in cancer treatment.

Liposome size and the amount of drug that can be loaded into liposomes is key in terms of the drugs’ pharmacodynamic and pharmacokinetic parameters. DLS can help to provide accurate information about the size of liposomes, which is critical to ensuring that drug delivery systems are effective. The size of liposomes varies, but is typically around 100nm.

Brownian motion

Particles suspended in a liquid medium undergo Brownian motion, which is slower, the larger the particle is. The solvent molecules have more impact on the movement of smaller p articles, which therefore move more rapidly. In DLS, light scattering by the particles is used to monitor Brownian motion.

The light scattering that occurs when a light is shone onto particles in solution can provide useful information about the size, weight, surface structure, charge, stability and concentration of the particles. Analysis over time can also provide information about changes in the solution. Researchers can learn about the interactions between particles in the fluid, as well as other aspects such as thermal melting points.

Dynamic light scattering technique

The speed that particles diffuse at as a result of Brownian motion is calculated by measuring the rate of fluctuation in the intensity of the scattered light. The intensity fluctuates more rapidly with small particles than it does with large particles.

The fluctuation is measured by comparing the signal intensity at one time with signal intensity a very short time later. With larger particles, it takes a long time for the correlation of the signal to decay, whereas the more rapid movement of smaller particles means the correlation of the signal decreases more quickly.

This change indicates the size of the particle and provides what is referred to as the hydrodynamic diameter, since the value refers to how the particle diffuses in solution.

References

Further reading:

Effect of fluorescent staining on size measurements of polymeric nanoparticles using DLS and SAXS: http://pubs.rsc.org/EN/content/articlelanding/2015/ay/c5ay02005k#!divAbstract

Further Reading

Last Updated: Jul 19, 2023

Deborah Fields

Written by

Deborah Fields

Deborah holds a B.Sc. degree in Chemistry from the University of Birmingham and a Postgraduate Diploma in Journalism qualification from Cardiff University. She enjoys writing about the latest innovations. Previously she has worked as an editor of scientific patent information, an education journalist and in communications for innovative healthcare, pharmaceutical and technology organisations. She also loves books and has run a book group for several years. Her enjoyment of fiction extends to writing her own stories for pleasure.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Fields, Deborah. (2023, July 19). Using Dynamic Light Scattering (DLS) for Liposome Size Analysis. News-Medical. Retrieved on April 26, 2024 from https://www.news-medical.net/life-sciences/Using-Dynamic-light-scattering-(DLS)-for-liposome-size-analysis.aspx.

  • MLA

    Fields, Deborah. "Using Dynamic Light Scattering (DLS) for Liposome Size Analysis". News-Medical. 26 April 2024. <https://www.news-medical.net/life-sciences/Using-Dynamic-light-scattering-(DLS)-for-liposome-size-analysis.aspx>.

  • Chicago

    Fields, Deborah. "Using Dynamic Light Scattering (DLS) for Liposome Size Analysis". News-Medical. https://www.news-medical.net/life-sciences/Using-Dynamic-light-scattering-(DLS)-for-liposome-size-analysis.aspx. (accessed April 26, 2024).

  • Harvard

    Fields, Deborah. 2023. Using Dynamic Light Scattering (DLS) for Liposome Size Analysis. News-Medical, viewed 26 April 2024, https://www.news-medical.net/life-sciences/Using-Dynamic-light-scattering-(DLS)-for-liposome-size-analysis.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.