MarginProbe System meets its primary endpoints: Dune Medical Devices

NewsGuard 100/100 Score

Dune Medical Devices, Inc. today announced that the landmark, 664-patient pivotal trial evaluating the MarginProbe™ System met its primary endpoints. The MarginProbe System provides surgeons with a real time, intraoperative technology to detect microscopically-positive margins on excised tissues. Top-line data from the study were presented at the 12th Annual Meeting of the American Society of Breast Surgeons (ASBS) in Washington, DC. Results showed that, when using MarginProbe in addition to standard of care techniques, there was greater than a three-fold increase in surgeons' ability to identify and immediately resect all positive lumpectomy margins, compared to standard of care techniques alone. This improvement led to a 57 percent reduction in patients who were candidates for re-excision (additional surgery) due to positive margins left un-resected on the lumpectomy specimen.  

A successful lumpectomy requires cancer-free margins at the edges of excised tissue.  However, intraoperative methods currently available to surgeons are limited in their ability to identify microscopically positive margins.  Because of this, patients frequently require re-excision when positive margins are found during pathological examination, normally occurring 2-4 days following lumpectomy.  Re-excision rates for positive margins are reported as high as 30 percent.  

Patients participating in the international, multi-center, controlled trial underwent lumpectomy surgery and were randomized in the operating room to receive either the standard of care (control group), or the standard of care plus MarginProbe (device group). In the device group, MarginProbe was used to measure each margin of the excised lumpectomy specimen. If the device registered a positive reading, additional tissue was immediately resected from the adjacent breast cavity surface.

A primary endpoint of the study was Complete Surgical Resection (CSR), which measured the surgeons' ability to identify and resect all positive margins when present.  Roughly 50 percent of patients had one or more positive margins on the lumpectomy specimen (later determined by pathology), and CSR was successful when all margins were identified and completely resected.  For the device group, the rate of successful CSR was 72 percent, compared to 22 percent in the control group (P<0.0001). Patients who did not achieve successful CSR were considered candidates for re-excision procedures, 42 in the device group compared to 98 in the control group (57 percent reduction, P<0.0001). Of these candidates, 30 patients in the device group and 62 patients in the control group had a re-excision.

"The results of the study are very encouraging," said International Principal Investigator Lorraine Tafra, MD, FACS, Medical Director of Anne Arundel Breast Center, Annapolis, MD. "The ability to accurately identify cancer immediately in the operating room, and have a marked impact on the number of patients who return from surgery with clear margins, suggests that the MarginProbe System has the potential to significantly improve traditional breast cancer surgery outcomes."

Readmissions for re-excision to obtain clear margins have been shown to increase cost and emotional distress for patients, as well as have the potential for more scarring and deformation at the surgical site.  

"Despite best efforts, achieving microscopically-clear surgical margins in the operating room has been a persistent challenge," said Dune Medical CEO, Bill Densel. "We are extremely pleased with the positive outcome of the study. These results confirm that our breakthrough technology can benefit patients by providing physicians with the ability to detect cancerous tissues during procedures and immediately react."

Pivotal Study Details

664 women aged 18 years and older, histologically diagnosed with carcinoma of the breast, with non-palpable malignant lesions requiring image guided localization, and undergoing lumpectomy surgery at one of 21 sites in the U.S. and Israel, were enrolled in the study.  Of these women, 596 were randomized in the operating room to one of two evenly distributed groups, either device or control.  In the device group, the MarginProbe System was used in addition to standard of care methods to measure each margin of the excised lumpectomy specimen. If the device registered a positive reading, additional tissue was immediately resected from the breast cavity corresponding to the positive margin. All tissue, in both groups, underwent intraoperative specimen imaging before being sent to routine pathology per standard of care.

A primary endpoint of the study was Complete Surgical Resection (CSR), the rate of patients with one or more positive margins (< 1mm) on the lumpectomy specimen, as determined by histology, in whom all positive margins were identified and immediately resected. In the device arm, the rate of CSR was 72 percent>

No safety concerns were noted in the study.  Events were similar across both study groups.

SOURCE Dune Medical Devices, Inc.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Breakthrough imaging method enhances precision in prostate cancer treatment