Researchers develop point-of-care device to facilitate monitoring of hereditary and hepatic metabolic disorders

NewsGuard 100/100 Score

Ammonium is a biomarker used to diagnose a series of rare hereditary metabolic disorders, such as the primary disorders of the urea cycle and different organic acidemias, as well as other metabolic and environmental conditions affecting the liver's function, which can cause a secondary dysfunction of the urea cycle. Ammonium is also useful in the study and monitoring of different hepatopathies (diseases affecting the normal functioning of the liver) caused by the consumption of alcohol or other drugs, medicines and other environmental factors.

In all of these disorders, an excess of ammonium is produced, putting the patient's health at risk. Values surpassing 200 micromoles per liter of blood are considered severe cases of hyperammonemia (high concentration of ammonium in blood) which can cause irreversible damage to the brain, and can even lead to death, if values surpass 500 micromoles per liter. Therefore, an early diagnosis in real time is crucial to minimizing the impact of a hyperammonemia episode on neurological functions. Currently, patients diagnosed with disorders which include hyperammonemia episodes must periodically be visited at hospital, where a blood sample is taken, which then must be treated and analyzed in the lab.

Researchers from the Sensors and Biosensors (GSB) research group of the Department of Chemistry at the UAB, in collaboration with the Hospital Sant Joan de Déu and the UPC, have developed a point-of-care (POC) analyzer that monitors the level of ammonium in patient's blood using a decentralized method at the point-of-care, instead of sending blood samples to be analyzed in hospital laboratories, where traditional equipment is used. The new device aims to decentralize the blood ammonium determination, making the analysis possible at smaller healthcare centers with direct blood measurements and no need for previous treatments. This would represent multiplying the number of monitoring sites, simplifying the process and reducing the time needed to take medical decisions.

Increasing the frequency of blood analyses to determine ammonium levels is of vital importance."

Mar Puyol, director of the study, UAB researcher

She goes on to say that: "Reducing the excess of ammonium in a patient with hyperammonemia is done by restricting protein intake, using drugs to enhance ammonium elimination, and dialysis and hemofiltration in the most acute cases, so that the evolution of the patient will be more favorable the faster the doctors act, and that can be achieved by using the point-of-care analyzers such as the one we have developed".

Validation at hospital

The research team is preparing a prototype that will function under semi-autonomous conditions. Once the device is ready, it will measure all ammonium samples analysed each day at the Hospital Sant Joan de Déu with the conventional method and with the new equipment created by researchers. Nevertheless, Puyol warns that "hundreds of samples will be necessary before the final prototype of the point-of-care analyser is validated. The next stage will then be industrialising the device to launch it into the market. There are still several stages before reaching that scenario, but the device is expected to become an economic alternative that can facilitate the monitoring of liver diseases in developing countries as well".

Functioning of the device

The device uses a microfluidic platform which includes a potentiometric detection system and a gas separation membrane. In this manner, it is possible to automatically separate the ammonium in the form of ammonia from the rest of the complex matrix of blood, obtaining a selective detection free of any other type of interferences. This guarantees a precise and exact determination of ammonium concentration in whole blood and not in plasma, which is the method conventionally used to analyse this parameter.

The study, directed by researchers Julián Alonso-Chamarro and Mar Puyol Bosch, from the Sensors and Biosensors Research Group of the Department of Chemistry at the UAB, is the result of a Proof of Concept R&D&I project (PDC2021-121558-I00), conducted in collaboration with researchers Rafael Artuch from the Hospital Sant Joan de Déu (HSJD) and Javier Rosell from the UPC's Research Centre for Biomedical Engineering (CREB). This study includes the support and involvement of the Fundación PKU-OTM (phenylketonuria and other hereditary metabolic disorders). The validation of the system is conducted at the Hospital Sant Joan de Déu in Barcelona.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Gut bacteria play a pivotal role in obesity's impact on body fat metabolism