Applications of Parallel Accumulation and Serial Fragmentation (PASEF)

Parallel accumulation – serial fragmentation (PASEF) is a spectroscopic technique used during liquid chromatography-mass spectrometry (LC-MS) based proteomics to improve sequencing speed and sensitivity.

Bottles for use in PASEF - a photo by RueangwitRueangwit | Shutterstock

What is the mechanism of PASEF?

PASEF traps precursor ions eluted during liquid chromatography in a tunnel, where they are accumulated and ordered depending on their collisional cross-sectional area and charge. Precursor ions are held stationary in equilibrium within the tube by opposing electric field and gas flow forces and are eluted by controlled reduction of the strength of the electric field.

This massively improves the sensitivity and speed of LC-MS, as precursor ions of identical species elute in a highly concentrated batch that mitigates the downsides of faster mass spectrometry mass spectra acquisition.

PASEF in shotgun proteomics

Shotgun proteomics is a bottom-up proteomics technique that identifies proteins in a complex mixture using liquid chromatography to separate precursor ions and known data to select precursor ions for fragmentation and analysis by mass spectrometry.

The random nature of shotgun proteomics often obstructs low abundance fragments in a sample containing a high concentration of other fragments, while the data dependent selection procedure may discard precursor ions of investigative value before the fragmentation step. PASEF overcomes these disadvantages as different ions with identical mass-to-charge ratio are further separated by their collisional cross section within the PASEF tunnel.

PASEF in single-run proteomics

Adjusting the elution time of precursor ions in the PASEF tunnel adjusts the number of generated fragments. Slower elution time fragments fewer precursors per PASEF scan, leading to a greater resolution between precursors of differing mobility.

A faster elution time means that fewer precursors pass through the tunnel per scan, though a far larger number of total scans are done during the process. Since precursors accumulate in the PASEF tunnel based on their charge, mass, and cross-sectional area, elution times can be faster without loss of sensitivity and with good signal to noise ratio. LC-MS procedures with PASEF tunnels can acquire many thousands of spectra at ten to twelve times faster rate than regular LC-MS methods.

PASEF with limited sample amounts

PASEF is well suited for small samples. The pre-accumulation of precursor ions into groups to improve the signal to noise ratio, greater separation between species depending on charge, mass, and cross-sectional area, allow PASEF to be highly sensitive even for small sample amounts. Traditional LC-MS methods require 100–200 ng to provide reliable and well-resolved spectra.

With PASEF, protein masses as low as just 10 ng can be used to reliably identify highly abundant proteins in the sample. Typical cells contain approximately 150 pg of proteins, meaning that just 60 cells are enough to generate MS mass spectra. This is ideal in a clinical setting, such as when performing a biopsy of a tumor.

PASEF in quantitative proteomics

Quantitative proteomics determines the concentration of particular proteins in a sample. PASEF improves the ability to determine the abundance of proteins due to a greater number of spectra generated per run, in addition to the reduced incidence of co-elution and co-isolated precursor ions.

Further Reading

Last Updated: Jan 17, 2019

Michael Greenwood

Written by

Michael Greenwood

Michael graduated from the University of Salford with a Ph.D. in Biochemistry in 2023, and has keen research interests towards nanotechnology and its application to biological systems. Michael has written on a wide range of science communication and news topics within the life sciences and related fields since 2019, and engages extensively with current developments in journal publications.  

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Greenwood, Michael. (2019, January 17). Applications of Parallel Accumulation and Serial Fragmentation (PASEF). News-Medical. Retrieved on October 31, 2024 from https://www.news-medical.net/life-sciences/Applications-of-Parallel-Accumulation-and-Serial-Fragmentation-(PASEF).aspx.

  • MLA

    Greenwood, Michael. "Applications of Parallel Accumulation and Serial Fragmentation (PASEF)". News-Medical. 31 October 2024. <https://www.news-medical.net/life-sciences/Applications-of-Parallel-Accumulation-and-Serial-Fragmentation-(PASEF).aspx>.

  • Chicago

    Greenwood, Michael. "Applications of Parallel Accumulation and Serial Fragmentation (PASEF)". News-Medical. https://www.news-medical.net/life-sciences/Applications-of-Parallel-Accumulation-and-Serial-Fragmentation-(PASEF).aspx. (accessed October 31, 2024).

  • Harvard

    Greenwood, Michael. 2019. Applications of Parallel Accumulation and Serial Fragmentation (PASEF). News-Medical, viewed 31 October 2024, https://www.news-medical.net/life-sciences/Applications-of-Parallel-Accumulation-and-Serial-Fragmentation-(PASEF).aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.