St. Jude Medical, Inc. (NYSE:STJ), a global medical device company, today announced U.S. Food and Drug Administration (FDA) approval and first U.S. implants of its Unify™ cardiac resynchronization therapy defibrillator (CRT-D) and Fortify™ implantable cardioverter defibrillator (ICD). The new devices feature advanced battery technology and circuitry that allow for the smallest device footprint in the industry and rapid charge times, without any compromise in device longevity or power.
“These devices offer a number of new features designed to address many of the clinical issues facing our patients while still delivering the reliability, power and longevity I expect from a St. Jude Medical device”
The Unify CRT-D and Fortify ICD have 45J of stored energy and can deliver 40J, the highest energy of any ICD available today. This high energy capacity gives these devices the ability to provide a greater safety margin, which could increase the chances that therapy will be successful for patients who may need more energy to correct their heart rhythm. Increasing the chance that therapy will be successful also decreases the chance that additional electrodes, such as a subcutaneous lead, will be required to defibrillate the heart. The energy capability of a device is particularly important for patients who have an enlarged heart, low ejection-fraction, advanced heart failure or previously demonstrated a high defibrillation threshold (the amount of energy required to shock the heart back to a normal rhythm).
The devices' narrow shape, along with their small footprint, allows physicians to implant them using a smaller incision, leading to less time spent closing the incision and a reduced scar for the patient. The company's SJ4 lead connector system further streamlines the procedure by reducing the number of set screws and connections between the defibrillation lead and the device, which can improve patient comfort by reducing the bulk of wires in the patient's chest.
"These devices offer a number of new features designed to address many of the clinical issues facing our patients while still delivering the reliability, power and longevity I expect from a St. Jude Medical device," said Dr. Robert P. Styperek, F.A.C.C., Harbin Clinic Physician, Director of Electrophysiology, at Redmond Regional Medical Center in Rome, Ga. "The devices' smaller shape, combined with the SJ4 connector system, streamlines the implant procedure and can make the device more comfortable for patients. To become accustomed to this outstanding improvement, all I need to do now is shorten the length of my incision."
Both devices also have features designed to reduce inappropriate or unnecessary defibrillation therapy, while ensuring effective therapy occurs when the patient needs it. The features include advanced sensing technology and more anti-tachycardia pacing options, which can convert many fast ventricular arrhythmias painlessly and avoid the need for high voltage shocks.