Scientists develop new software to test alterations in night vision

NewsGuard 100/100 Score

Researchers from the Department of Optics of the University of Granada, belonging to the Laboratorio de Ciencias de la Visi-n y Aplicaciones, have developed a programme for testing alterations in night vision, and the tool required to implement it, which has been named "halometer".

This instrument consists on a software named Software Halo v1.0, and a computer where the mouse is used as a response button, and a chin cup with a forehead holder to fix the observer's position. Software Halo v1.0 was initially presented as freeware available on LabVisGra's website at http://www.ugr.es/local/labvisgr and at the University of Granada's institutional repository at http://digibug.ugr.es/handle/10481/5478. Nevertheless, it was recently released by the Free-Software Bureau of the University of Granada so, it has become a scientific freeware application.

This software was developed by a group coordinated by Rosario Gonz-lez Anera, receiving technical support of the Granadian company Seven Solutions and of an ophthalmological clinic set in Madrid and named Novovision. The research group was integrated by researchers Jos- Juan Castro, Carolina Ortiz and Aixa Alarc-n, and receives fundings from the regional government of Economy, Innovation and Science of the Junta de Andaluc-a.

Low-Light Conditions

Before the test, researchers fix the observer's position with a chin cup and a forehead holder at an adequate distance from the monitor where the test will be displayed and considering the angular diameter that light stimuli must have. The test is performed under low-light conditions (in a dark room) and, before the test, patients are given some minutes to adapt to darkness.

This test involves showing a bright light stimulus to the subject against a dark background and, progessively showing different peripheral light stimuli -with lower brightness around the central (Figure 2), at random, in different positions and at different distances. Subjects' task is to press the buttom of a mouse every time they detect a peripheral stimulus. Once the test ends, the software makes an estimation of a parameter named "Visual Disturbance Index" that, together with the results graphic, determines the type and intensity of visual disturbance.

This index scores from 0 to 1, so the higher is this index, the stronger is the influence of the halo or any other visual disturbance perceived by the observer. Therefore, the lower is the subject's ability to detect the peripheral stimuli displayed around the main stimulus that causes such disturbances.

One of the advantages of the halometer developed at the University of Granada is that it allows to configure such test parameters as:

  • Special parameters: the radius of the central stimulus and the peripheral stimuli can be modified. Furthermore, the number of semi-major axes where the peripheral stimuli will be displayed can be fixed, as well as the maximum radius -maximum distance between these stimuli-, and the number of stimuli per semi-major axe.

  • Temporary Parameters: the software allows to set some exposure time for adaptation to darkness and to the brightness of the central stimulus. Furthermore, others parameters as the exposure time to the stimulus and the time elapsed between a stimulus and the next one can also be set.

  • The software also allows to set the color and brightness of central and peripheral stimuli, and the weight and number of times each peripheral stimulus is shown.

This test has been tried with different observer groups consisting of people operated on cataract or submitted to refractary eye surgery, with normal observers and patients with different eye pathologies as AMD (Age-related Macular Degeneration) and unilateral keratitis. The results obtained showed that, in the case of patients with keratitis, the visual disturbance index for the healthy eye was found to be lower than that for the unhealthy eye, and even lower under binocular vision conditions. However, visual disturbance indexes proved to be higher in the case of patients operated on cataracts, showing a higher influence of halos and, therefore, lower detection capacity. Patients operated with LASIK refractory eye surgery also presented high vision disturbance indexes in comparison to normal observers.

The results obtained with this halometer and the new software have been presented in different national and internacional conferences as the IX Reuni-n Nacional de -ptica, Galice and the Wavefront Confress 2009. furthermore, a research article has been published in the international journal Applied Optics describing the results obtained with patients operated with refractory eye surgery. It has also been recently admitted for publication in the prestigious scientific journal Journal of Biomedical Optics, where the results obtained with patients with different eye pathologies are described.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Combining health data with whole genome sequence data in cancer patients can help doctors provide more tailored care