Colonoscopies done with suboptimal bowel preparation linked to high adenoma miss rates

NewsGuard 100/100 Score

A new study reports that colonoscopies done with suboptimal bowel preparation are associated with relatively high adenoma (precancerous polyp) miss rates, suggesting that suboptimal bowel preparation substantially decreases colonoscopy effectiveness and may mandate an early follow-up examination. In this study, in the context of suboptimal bowel preparation, of all adenomas identified, 42 percent were discovered only during a repeat colonoscopy, which was necessitated by an inadequate preparation during the first colonoscopy. The study appears in the June issue of GIE: Gastrointestinal Endoscopy, the monthly peer-reviewed scientific journal of the American Society for Gastrointestinal Endoscopy (ASGE).

Colorectal cancer develops slowly, therefore screening for the disease is especially important. Colonoscopy screening allows for the detection and removal of precancerous polyps (small growths in the colon) during the same exam and before the polyps turn into cancer. One of the most important steps in colonoscopy is patient bowel preparation. Adequate preparation ensures that the colon is thoroughly cleaned before the exam so that the physician can clearly see the entire colon to look for abnormalities, such as colon polyps, during the procedure. Cleansing the colon before a colonoscopy is called bowel preparation, or "prep." It involves taking medication that causes diarrhea, emptying the colon. The medication is taken by mouth, and comes in liquid or tablet form. Patients also need to change what they eat during the day or two before the colonoscopy.

The effectiveness of any colorectal cancer screening program is critically dependent on adequate bowel preparation. Suboptimal bowel preparation is associated with a decreased ability to detect adenomas. Additionally, poor preparation increases the total cost of colonoscopy by virtue of the need for repeat examinations at shorter than usual intervals. Suboptimal bowel preparation occurs in more than 20 percent of all colonoscopic examinations, yet guidelines do not specify the appropriate time interval in which to repeat the exam in this setting. Guidelines do specify recommended intervals between colonoscopies depending on colonoscopic and histologic findings presuming an optimal bowel preparation. Otherwise, it is left to the individual colonoscopist to decide how to adapt the recommended guidelines to cases with suboptimal bowel preparation.

"We aimed to identify factors associated with the decision to repeat the examination early after a colonoscopy done with suboptimal bowel preparation. We also aimed to quantify adenoma miss rates among those pairs of colonoscopies separated by an interval shorter than the time suggested by current guidelines, which assume an optimal bowel preparation," said study lead author Benjamin Lebwohl, MD, MS, Columbia University Medical Center, New York, N.Y. "Our findings of a miss rate of 42 percent for all adenomas and 27 percent for advanced adenomas suggest that suboptimal bowel preparation has a substantial harmful impact on the effectiveness of colonoscopy, and follow-up examination within one year should be considered. Because neoplastic findings on the initial colonoscopy were associated with a greater miss rate, a repeat examination within one year is indicated when an adenoma is found during a colonoscopy with suboptimal bowel preparation."

Methods

The study objective was to identify factors associated with early repeat colonoscopy after initial examinations with suboptimal preparations and to measure adenoma miss rates in this context. Early repeat colonoscopy was defined as any colonoscopy that was performed within three years of the initial examination. Three years is the shortest interval recommended in the current guidelines for surveillance colonoscopy in patients with a completely excised advanced adenoma or multiple adenomas found on the initial examination. In turn, any colonoscopy repeated before three years represents an examination repeated earlier than suggested by guidelines. Sensitivity analyses also were performed by using a more stringent definition of an early repeat examination, which was one repeated within one year of the initial examination.

To quantify the yield of repeating the colonoscopy early in terms of adenoma detection, the researchers included all patients in whom the cecum was reached on both the initial and repeat examination and in whom bowel preparation quality was considered optimal on the repeat examination. Adenoma miss rates for repeated colonoscopies were calculated by dividing the total number of adenomas found on the second colonoscopy by the total number of adenomas found on the index colonoscopy plus the second colonoscopy.

Results

The researchers concluded that although a minority of patients undergo early repeat examination after colonoscopies done with suboptimal bowel preparation, the miss rates for colonoscopies done with suboptimal bowel preparation were high, suggesting that suboptimal bowel preparation substantially decreases colonoscopy effectiveness and may mandate an early follow-up examination. They also noted that there was wide variation between physicians with regard to the decision to repeat colonoscopies early in this setting. The researchers stated that to the best of their knowledge, there are no other studies that have determined adenoma miss rates secondary to suboptimal bowel preparation by using repeat colonoscopy data from the same patients.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Study unveils novel bladder cancer diagnostic model based on key mitochondrial genes