New Endoscopic Technique

NewsGuard 100/100 Score

A flexible wide-field endoscope utilising blue excitation light provides label-free contrast of tissue based on fluorescence lifetime imaging of tissue autofluorescence.

London (UK) – Fluorescence lifetime imaging (FLIM) of tissue autofluorescence has been shown to provide labelfree contrast between different types and states of tissue. Clinical FLIM can combine lifetime contrast with morphological information to provide a direct comparison between different spatial regions – making it easier to spot differences with respect to “normal” tissue, e.g. for diagnostic screening and potentially enabling margins of diseased tissue to be identified. To date, however, there have been relatively few clinical FLIM studies, partly due to a lack of suitable instrumentation.

With the aim of applying FLIM to detect and monitor disease in internal organs such as the colon, a British team led by Hugh Sparks (Imperial College London) now developed a flexible wide-field FLIM endoscope based on coherent optical fibre bundles. The device utilizes low average power blue picosecond laser diode excitation sources to induce tissue autofluorescence. Its multimode optical fibre efficiently delivers the excitation radiation to illuminate a 3 mm field of view.

Unfortunately, the multimodal optical fibre propagation necessary to achieve this broad illumination can lead to errors in the lifetime determination due to temporal broadening of the excitation pulses. To address this issue, the researchers characterized the consequent degradation of the spatio-temporal instrument response function (IRF) and incorporated a spatially varying temporal instrument response function in the FLIM analysis.

As prove of principle, the scientists applied their new FLIM endoscope to ex vivo tissue autofluorescence from diseased human larynx biopsies. Using a gain-switched picosecond diode laser operating at 445 nm as the excitation source and an average excitation power of circa 0.5 mW, mmscale spatial maps of autofluorescence lifetimes could be acquired in about 8 seconds.

To illustrate the instrument’s potential for FLIM at higher acquisition rates, a higher power modelocked frequency doubled Ti : Sapphire laser was used to carry out FLIM of ex vivo mouse bowel at up to 2.5 Hz using 10 mW of average excitation power at the specimen.

The results demonstrate the potential of the technique to screen for neoplasia. Based on the flexible wide-field FLIM endoscope, new clinical instrumentation may be developed to aid diagnosis and monitoring of therapeutic interventions.

(Text contributed by K. Maedefessel-Herrmann)

See the original publication: Hugh Sparks, Sean Warren, Joana Guedes, Nagisa Yoshida, Tze Choong Charn, Nadia Guerra, Taranjit Tatla, Christopher Dunsby, and Paul French, A flexible widefield FLIM endoscope utilising blue excitation light for label-free contrast of tissue, J. Biophotonics 8:1, 168-178 (2015); doi: http://dx.doi.org/10.1002/jbio.201300203

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Study shows daily glucose levels fluctuate more than we thought, challenging diabetes diagnosis