Sensor technology has potential to improve teaching of proper CBE techniques

NewsGuard 100/100 Score

Sensor technology has the potential to significantly improve the teaching of proper technique for clinical breast exams (CBE), according to a new study by researchers at the University of Wisconsin School of Medicine and Public Health.

The results of the study were published in a correspondence today in the New England Journal of Medicine.

Carla Pugh, director of patient safety and education at the University of Wisconsin Hospital and Clinics and principal investigator of the study, says the use of sensors allows a level of critical analysis unavailable to clinicians until recently.

"Variations in palpable force used during a CBE cannot be reliably measured by human observation alone," Pugh says. "Our findings revealed that 15 percent of the physicians we tested were using a technique that put them at significant risk of missing deep tissue lesions near the chest wall. This research underscores the potential for sensor technology to be used not only to improve clinical performance, but to also allow for objective evidence-based training, assessment and credentialing."

For the study, Pugh and her team asked 553 practicing physicians during annual clinical meetings of the American Society of Breast Surgeons, American Academy of Family Physicians and American College of Obstetricians to perform simulated CBE under conditions that mimic an office visit for a symptomatic patient. Participants completed a demographic survey, reviewed a clinical scenario, performed the CBE on a sensor-enabled breast model, and then documented their findings. The goal was to capture CBE technique while clinicians were purposefully seeking a mass.

The sensor data revealed that physicians who palpated fewer than 10 newtons (a common measurement of force) were able to find two superficial masses on the breast model but missed the two deeper ones. The physicians who increased the amount of palpation pressure improved the probability that they would identify the deeper lesions. The study suggests that the optimal palpable force for deeper lesions is between 12 and 17 newtons.

"I want to spark a serious conversation about the potential for high-end, mastery training in the health care profession," Pugh says. "Health care is at a critical juncture where there are huge opportunities for major information exchanges that can empower physicians and patients. Both patients and physicians will benefit from clinical-skills performance data."

In 2011, Pugh received the Presidential Early Career Award for Scientists and Engineers (PECASE) for her research on the sensor device used in the study. Other researchers on this project include Shlomi Laufer, a research fellow in Pugh's lab, and Anne-Lise D'Angelo, a resident in the division of general surgery at the UW Hospitals and Clinics and a graduate student in educational psychology at UW-Madison.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Chatbots for mental health pose new challenges for US regulatory framework