Dual breast exam using MRI and NIRST more accurate than MRI alone

NewsGuard 100/100 Score

By combining two modalities of imaging, investigators from Norris Cotton Cancer Center at Dartmouth, led by Keith Paulsen, PhD with first author Michael Mastanduno and collaborators from Xijing Hospital in Xian, China, demonstrated that a dual breast exam using MRI and Near Infrared Spectral Tomography (NIRST) is feasible and more accurate than MRI alone. Their paper, "MR-guided Near Infrared Spectral Tomography Increases Diagnostic Performance of Breast MRI," was published in Clinical Cancer Research.

"The research is exciting because it shows for the first time, in the largest clinical study to date of the combined MRI+NIRST imaging approach, that improvement in the specificity of breast MRI is possible by adding NIRST to the imaging procedure," explained Paulsen. "Other reports suggested that such improvement was possible, but they included small numbers of clinical exams that were not sufficiently large enough to show a statistically significant improvement."

Breast MRI is the most sensitive imaging technique for cancer surveillance and is recommended for screening in women with elevated risk of breast cancer. Unfortunately, breast MRI generates many "false positives," which are regions of the breast that "enhance" under imaging technology, but are not malignant. Better imaging could provide additional information for clinicians and potentially reduce the number of MRI-guided biopsies.

Paulsen's study investigated whether the addition of molecular imaging (NIRST) at the time of MRI would improve the diagnostic accuracy of breast MRI alone by contributing functional information about regions of suspicion in the breast identified by the MRI and helping to categorize the regions as malignant or benign. The study showed that data from the combined imaging procedure improved specificity of the exam from 67% for MRI alone, to 89% when TOI (tissue optical index) from NIRST imaging was added. The sensitivity did not decrease, remaining high at 95%, and the AUC (area under the curve) increased to 0.95 from 0.86 for MRI alone.

"Working with our Chinese colleagues at Xijing Hospital, we found that a combined MRI+NIRST breast exam is feasible as a clinical breast imaging procedure, and that the data from the combined imaging modalities is diagnostically more accurate," said Paulsen. "In particular, this combination improves on what is reported by breast MRI alone. With additional technical improvements related to exam set-up and delivery, the approach is ready for evaluation in larger clinical studies, including multi-center trials."

Looking forward, Paulsen plans to refine the technology to improve its clinical acceptance, making it easier to use and seamless in the standard clinical workflow of breast MRI, as well as increasing the areas of breast coverage with the NIRST sensors.

Source: Norris Cotton Cancer Center at Dartmouth-Hitchcock

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Breast cancer survivors at higher risk of developing second cancers