A first-in-human study of a new polymer-free drug-filled stent, which provides controlled drug elution from an internal lumen, indicated non-inferior in-stent late lumen loss at nine-months compared with historical zotarolimus-eluting stent (Resolute) data. In addition, there was no binary restenosis, and a high degree of early stent strut coverage with minimal malapposition.

Findings from the REVELUTION study were reported today at the 28th annual Transcatheter Cardiovascular Therapeutics (TCT) scientific symposium. Sponsored by the Cardiovascular Research Foundation (CRF), TCT is the world's premier educational meeting specializing in interventional cardiovascular medicine. The study was also published simultaneously in JACC: Cardiovascular Interventions.

A polymer-free metal surface stent that is capable of controlled antiproliferative drug elution may avoid the adverse effects of polymer-induced inflammation, thrombosis and non-uniformity, and could potentially allow for shorter durations of dual antiplatelet therapy. The polymer-free drug-filled stent (DFS) used in the study was designed to provide controlled and sustained drug elution from an internal stent lumen without a polymer coating. The DFS is made from a tri-layered continuous wire with an outer cobalt chromium layer, a middle tantalum layer, and an inner lumen coated with sirolimus. Small laser-drilled holes on the abluminal stent surface control drug elution.

The study enrolled 100 patients with de novo coronary lesions 2.25-3.50 mm in diameter and length ≤ 27 mm in two 50-patient cohorts for angiographic, intravascular ultrasound, and clinical assessment at nine or 24 months, with optical coherence tomography (OCT) performed in a subset of 30 patients at multiple time periods. The primary endpoint was angiographic in-stent late lumen loss at nine months compared with historical data from the zotarolimus-eluting stent (Resolute) as a control. Fifty patients with 56 lesions were treated with DFS in the nine-month cohort. Researchers found in-stent late lumen loss was 0.26±0.28 mm for DFS and 0.36±0.52 mm for Resolute (Pnoninferiority<0.001). The binary angiographic restenosis rate was 0%. Median stent strut coverage by OCT was 91.4%, 95.6%, and 99.1% at one, three, and nine months, respectively. One non-Q-wave myocardial infarction occurred, with a nine-month target lesion failure rate of 2.1%. No stent thrombosis occurred.

"At nine months, the polymer-free drug-filled stent (DFS) was safe and effective with high rates of early strut coverage and non-inferior late lumen loss compared with historical Resolute data," said Stephen G. Worthley, MBBS, PhD, Chief Medical Officer of GenesisCare in Alexandria, Australia. "This polymer-free stent may avoid polymer-associated adverse vascular responses potentially allowing for a shorter duration of dual antiplatelet therapy. However, larger controlled studies with long-term follow-up are required to demonstrate whether the favorable properties of DFS translate into improved event-free survival in patients with coronary artery disease."

Source: Cardiovascular Research Foundation (CRF)

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Feeling lonely? It may affect how your brain reacts to food, new research suggests