Easily automate titrations, measure water content with Karl Fischer techniques, and run multiparameter assays using METTLER TOLEDO's modular autosamplers.

Start with the nine-position Rondolino, scale up to the single-row InMotionFlex™ that accommodates 11-50 samples, enhance throughput with the extending-arm InMotion Pro, capable of handling up to 182 samples, or operate overnight with the dual-tower InMotion Max, which can manage 303 positions.

The dedicated InMotion KF Ovens facilitate sealed-vial testing. OneClick, SmartSample, and LabX ensure that results are fully traceable.

Rondolino: The compact 9-sample carousel automates the daily quality control process.

InMotion Flex: Flex Base streamlines workflows involving one-row, 11-50 sample routine, mixed vials and beakers.

InMotion Pro: The extended-arm tower, equipped with water-bath racks, is capable of processing up to 182 samples.

InMotion Max: The dual-tower, water-bath system efficiently analyzes more than 300 samples completely overnight.

Unified platform: OneClick control, SmartSample IDs, and LabX e-signatures guarantee traceable and compliant throughput across all scales.

Highlight

Automated Karl Fischer water content determination

Observe the InMotion KF Flex oven as it pierces sealed vials, heats them to the ideal Temperature Scan set-point, and directs moisture into the titration cell under a digitally regulated gas flow. OneClick initiates the process, StatusLight indicates progress, and secure one-piece caps ensure that analysts remain safe from solvents.

InMotion Karl Fischer Titration Oven Autosampler - METTLER TOLEDO

High-throughput automation

Rondolino: The compact carousel automates nine quality control titrations as the user prepares the next batch.

InMotion Flex / Pro / Max: Flex accommodates a maximum of 50 samples; Pro's multi-row racks can handle over 180; Max processes more than 300, with each unit automatically dosing, rinsing, and performing unattended PowerShower cleaning.

InMotion KF: The dedicated Karl Fischer oven autosampler provides water-content determinations using the drying oven extraction method.

Parallel: Connect two autosamplers to one T9 for doubled throughput.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

Modular scalability

Snap-in modules: Incorporate pumps, burette drives, sensor boards, aliquot kits, and KF ovens.

Water-bath racks: Ensure accurate temperature regulation for each sample within the rack

Boost capacity: Exchange racks, incorporate an additional tower, or connect another autosampler

Parallel mode: Dual trays or twin towers conduct simultaneous titrations, effectively doubling the throughput.

User safety: CoverUp lids protect operators from unstable vapors and smelly solvents

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

Effortless compliance and data integrity

LabX audit trail: Each rack movement, solvent alteration, and outcome is recorded with time stamps in accordance with 21 CFR Part 11 / EU Annex 11 electronic signatures and user-role management.

Sample-centric security: SmartSample RFID or barcode associates the ID and weight of each vial with its corresponding rack position, thereby preventing any mix-ups.

Tamper-proof archiving: The run files and sensor-status snapshots are preserved in a redundant LabX database, ensuring they are inspection-ready for years.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

Intelligent workflow control

OneClick launch: Customized home screens initiate a complete rack run, autosampler, and titrator with just one tap.

Conditional logic: Pre-programmed Conditions activate particular actions, such as repeating, rinsing, or discarding, according to established criteria, thereby minimizing the need for manual oversight.

StatusLight signals: The tower LEDs illuminate in green, yellow, or red, providing an immediate indication of when to load, intervene, or allow the system to operate uninterrupted.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

Autosamplers and sample changers for every application

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

InMotion, InMotion-KF Ovens, and Rondolino

Automate titrations and Karl Fischer workflows at any scale. The compact Rondolino carousel accommodates nine samples, while the InMotion Flex, Pro, and Max can process between 11 and 303 beakers. Additionally, InMotion KF Ovens enhance the efficiency of sealed-vial moisture testing.

OneClick, SmartSample, PowerShower, water-bath racks, and LabX audit trails provide traceable, hands-free throughput, allowing analysts to focus on generating high-value, data-driven insights.

Sample changer

Rondolino sample changer

Nine-sample carousel automates standard titrations within a notebook-sized footprint, enabling busy laboratories to complete quality control while allowing operators to concentrate on more valuable tasks.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

General-purpose InMotion autosamplers

InMotion Flex autosampler

The autosampler can handle between 11 and 50 samples in a single run; rapid rack changes enable laboratories to transition from manual titration to automated efficiency while preserving current methodologies.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

InMotion Pro autosampler

The autosampler, featuring an extending arm and a multi-row design, is capable of preparing between 23 and 182 samples in a single sequence. This innovation allows analysts to work more efficiently and reduces turnaround times for mid to high-volume workflows.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

InMotion Max autosampler

Twin towers are designed to queue 24-303 samples, facilitating genuine overnight, hands-free operation. This feature is particularly advantageous when high throughput and reduced operator involvement are essential.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

InMotion Karl Fischer Oven autosamplers

InMotion KF Six Oven autosampler

The six-position oven carousel of the autosampler confirms water content in either duplicate or triplicate samples. It is the only KF oven compatible with EVA V1 and C1 titrators, making it suitable for low-volume, unattended operations.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

InMotion KF Flex Oven autosampler

The compact oven accommodates 26 sealed vials within a 25 cm footprint, providing dependable water content testing in routine quality control environments.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

InMotion KF Pro Oven autosampler (20 mL)

The Pro oven accommodates twenty 20 mL vials, enhancing high-capacity moisture workflows in laboratories focused on pharmaceuticals, polymers, and specialty chemicals.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

InMotion KF Pro Oven autosampler (10 mL)

The Pro variant includes twenty-four 10 mL vials, effectively balancing throughput and reagent consumption for standard water-content analysis.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

InMotion KF Pro Oven autosampler (5 mL)

The small-volume Pro rack accommodates twenty-six 5 mL vials, thereby reducing the amount of reagents used while ensuring accurate moisture measurements for valuable materials.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

Autosampler model comparison

Source: Mettler Toledo – Titration Systems

Key Feature Rondolino Sample
Changer
InMotion Flex
Autosampler
InMotion Pro
Autosampler
InMotion Max
Autosampler
InMotion KF
Flex Oven
InMotion KF
Pro Oven
InMotion KF
Six Oven
Max sample positions* 9 50 (25 mL) /
11 (250 mL)
182 (25 mL) /
23 (180 mL)
303 (25 mL) /
24 (250 mL)
26
(10 mL vials)
20 / 24 / 26
(rack dependent)
6
Rack Ø / footprint 25 ×35 cm Ø 42 cm tray, 25 cm wide base Ø 42 cm tray, 33 cm wide base Ø 57 cm tray, 33 cm wide base 25 cm wide
base
25 cm wide
base
25 cm wide
base
Second tower option Yes (except
25 mL rack)
Built-in twin towers Dual-autosampler link
PowerShowercleaning Optional – (oven) – (oven) – (oven)
SmartSample/ barcode ID ✓ full rack ✓ outer rows
Water-bath racks Optional Optional Optional
Suitable assays Routine titration QC Acid/base, redox, KF direct, multiparameter Medium–high-volume titrations, duplicate runs Overnight high-volume
titrations
Sealed-vial KF, daily QC High-throughput sealed-vial KF Duplicate/triplicate
KF spot
checks
Throughput style Sequential 11-50 samples, sequential 23-182 samples, sequential or duplicate 24-303 samples, overnight or duplicate 26 vials per rack, sequential Up to 120 vials per series, sequential 5 vials
per series
Typical lab size Small QC bench Growing labs upgrading from manual Mid-to high-volume QC Central QC / production labs Everyday KF Water Content Determination Pharma, chemical, battery QC Pilot plants, field labs
LabX/ OneClickintegration Yes Yes Yes Yes Yes Yes Local control (USB / network export)
Compliance & data Traceable runs via LabX 21 CFR 11 / Annex 11 with LabX Same Same Same Same Exports data to LIMS/USB

Elevate the autosampler with smart accessories

Scale InMotion autosamplers equipped with 11-303-place racks, CoverUp lids, water-bath trays, Aliquot dosing, PowerShower cleaning, SmartSample ID, along with a solvent manager or digital gas-flow control for KF ovens. Rondolino includes the optional PowerShower. OneClick automatically detects each add-on, enhancing throughput and data integrity while maintaining the same bench space.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

Application spotlight

Determining base number in motor oils via ASTM D4739

Quantification of additive content and monitoring of oil degradation are achieved through automated base number titration with HCl. This ASTM D4739-compliant method uses the T9 with InMotion Max to deliver efficient and repeatable results, making it suitable for petrochemical laboratories tracking motor oil performance over time.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

Determining kappa number in pulp samples with DispenSix

Lignin content analysis is automated using DispenSix and InMotion for redox back-titration with permanganate and thiosulfate. This ISO 302:2004-compliant approach ensures precise chemical dosing and reliable results, ideal for pulp and paper laboratories focused on optimizing bleaching processes and fiber characterization.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

Water content of lithium-ion battery electrolyte

Accurate water determination in lithium-ion battery electrolytes is performed using HYDRANAL NEXTGEN FA reagents combined with coulometric Karl Fischer titration. This method prevents side reactions and provides precise measurements even in the presence of additives, making it suitable for battery laboratories requiring ppm-level water control.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

Parallel titration of duplicates: Analysis with ion-selective electrodes

The analysis of calcium, fluorine, chloride, and copper is expedited by conducting duplicate titrations simultaneously with ion-selective electrodes. The InMotion + T9 setup increases sample throughput, ensures consistent results, and optimizes analyst productivity, ideal for quality control laboratories processing large sample volumes.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

Measuring water in protein powders with KF Oven

Water content in whey, casein, soy, and other products is measured using volumetric Karl Fischer titration with the InMotion KF Oven. This method guarantees accurate, decomposition-free moisture results, making it suitable for quality assurance laboratories monitoring the nutritional quality and shelf life of protein powders.

The InMotion™ Karl Fischer Autosampler for titration

Image Credit: Mettler Toledo – Titration Systems

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.