Why powder flowability matters in injectable implant manufacturing

Even precise shaping and cutting controls cannot always compensate for hard-to-feed materials. To address variability at the source, manufacturers benefit from understanding how powder behavior, material preparation, and feeding stability can mitigate it.

To produce injectable pharmaceutical implants with consistent dimensions, control is required throughout the production process. Hot-melt extrusion (HME) involves feeding a mixture of medication and polymer into an extruder, melting and mixing it, and then shaping it into a narrow strand that is cut into individual implants.

The dimensions of those implants are determined not only by the shape and cut of the strand, but also by the consistency with which the material enters the process.

Dr.-Ing. Margarethe Richter, Application Specialist at Thermo Fisher Scientific, says poor material flowability is one of the most common difficulties in pharmaceutical HME.

Fine active pharmaceutical ingredient (API) powders and polymers with challenging handling properties can cause material-feeding issues, compromising processing conditions and the consistency of the extruded strand.

For polymer-based implants planned to release medication over weeks, months, or years, such fluctuations can reduce the proportion of final implants that match dimensional criteria.

From starting material to finished implant

Once the drug-polymer mixture enters the extruder, it must be heated, mixed, and passed through the shaping die. However, generating a continuous strand is only part of the challenge; its dimensions must remain within specification as it approaches cutting.

A two-axis laser gauge measures the strand's diameter and ovality, and a feedback-controlled pulling mechanism changes line speed to help maintain the desired dimensions. After cooling and solidifying, the strand is cut into individual implants and separated according to dimensional requirements.

These controls help govern the dimensions of the end product, but they cannot eliminate every source of variation introduced earlier in the manufacturing process.

In the following poster walkthrough, Dr.-Ing. Margarethe Richter, application specialist at Thermo Fisher Scientific, discusses this integrated manufacturing sequence using the Thermo Scientific™ Pharma mini Implant Line.

Manufacturing Injectable Drug Delivery Implants Using Hot-Melt Extrusion Copy

YouTube video featuring Dr.-Ing. Margarethe Richter 

Why feeding consistency is difficult to maintain

Before melting and compounding begin, the physical qualities of the starting materials can present challenges.

Fine API powders can build an electrostatic charge and stick to feeder surfaces. Some polymers, such as poly(lactic-co-glycolic acid) (PLGA), might arrive as uneven flakes with low flowability. Materials may also condense or create bridges within a feeder, limiting the supply to the extruder.

These disturbances do not occur just at the feeder. Irregular material flow can produce oscillations in torque, pressure, and melt flow through the barrel and die, resulting in variations in extrudate diameter.

Small ophthalmic implant manufacturing necessitates a delicate balance between feeding accuracy and downstream handling. Individual implants may weigh only one to two milligrams, with feeding rates of 10–20 grams per hour.

Even at these low rates, manufacturing can be around 10,000 implants each hour. Small variations in material flow can thereby affect a large number of individual implants.

Simply raising the feed rate is not always the solution: a faster-moving strand may be harder to manage and cut consistently, whereas lower feed rates place a higher emphasis on feeding accuracy. The challenge lies in identifying operating parameters that provide steady material flow at a line speed that downstream equipment can handle.

When improving the process means preparing the material

An unsteady feed cannot usually be rectified by changing the extruder settings. Sometimes, the beginning material itself must be adjusted.

Richter provides an example of a low-density, lyophilized (freeze-dried) powder containing an API. The material arrived in huge, uneven bits that could not be fed consistently. Breaking the fragments into smaller pieces did not resolve the issue. Instead, needle-like particles developed, resulting in bridging and occlusion within the feeder.

The response was a preliminary twin-screw granulation procedure. Using a redesigned processing setup with an open discharge, the material was transformed into granules with improved flow behavior, resulting in steadier feeding.

Lyophilized powder before granulation

Lyophilized powder before granulation. Image Credit: Thermo Fisher Scientific – Production Process & Analytics

Material after granulation

Material after granulation. Image Credit: Thermo Fisher Scientific – Production Process & Analytics

Granulation is simply one possibility, not a universal answer. Depending on the formulation, milling, compaction, mixing, or pre-extrusion may all improve material handling. Each technique must be measured against the material's qualities, especially when working with polymers that are sensitive to thermal or mechanical processing.

The key takeaway is that enhancing extrusion performance may involve modifying the material entering the process, rather than simply changing what happens inside the extruder.

Questions for process development: Where can variability arise?

When establishing a process or evaluating uneven output, consider four parts of the manufacturing workflow:

  • Starting material: Can particle form, bulk density, or electrostatic behavior impact material flow?
  • Feeding: Is material reaching the extruder at the desired rate?
  • Extrusion: Do torque, pressure, and extrudate dimensions stay stable?
  • Downstream handling: Can measurement, pulling, and cutting maintain the required dimensions at the chosen throughput?

These questions can help identify areas where additional research or process changes would be most beneficial.

Consistency needs control throughout the process

Stable feeding is a good start, but it is not enough in isolation. Temperature, screw speed, shear, and residence time all have an impact on melt viscosity, mixing, and the material's susceptibility to heat and mechanical stress.

Processing conditions must allow biodegradable polymers, such as PLGA, to flow and form without generating unacceptable degradation. Downstream measurement, pulling, cutting, and sorting allow more control over finished dimensions.

Richter refers to injectable implants as a "product by process," indicating how closely the ultimate product is related to the conditions under which they are made.

For development teams dealing with inconsistent output, that perspective proposes looking beyond the point at which a problem becomes apparent. Understanding the initial material, its preparation, and its behavior during extrusion can help identify where variability occurs and which adjustments are most effective.

About Thermo Fisher Scientific – Production Process & Analytics

You increase food quality, ensure product integrity, or accelerate the development of the next generation of environmentally friendly energy solutions. In a highly competitive global marketplace, however, you face new internal and external pressures. Stringent regulatory mandates. Heightened consumer expectations. You need a partner with the stability and reliability to integrate proven solutions with your business complexities.

We’ve been at the forefront - and by your side - for over fifty years.

We identify. We verify. We simplify.

From the lab to the line and field, we enable our customers to make the world healthier, cleaner, and safer with world-class Thermo Scientific™ products and services.

Our innovative portfolio for Industrial and Safety Applications covers:

Advanced imaging: Our x-ray sources are deployed in a wide range of applications, for the testing, imaging, and inspection of items ranging from batteries, printed circuits boards and semi-conductor devices to animal fluoroscopy and dental prosthetics quality control. They have the short wavelengths and high energies required to penetrate through many different materials and provide a non-destructive, easy-to-use, reliable technology, in the laboratory, in healthcare settings or on-line. Learn more.

Bulk elemental analysis: For more than 85 years, Thermo Fisher Scientific has been a global supplier of spectrochemical instruments for major industries such as metallurgy, transportation, cement, mining, food, pharmaceuticals, chemicals, petroleum and batteries. We offer unparalleled capabilities in optical emission spectrometry (OES), laboratory X-ray fluorescence (XRF), X-ray diffraction (XRD) and spectrometer automation (SMS):

  • OES analyzers are ideal for use in quality control for the direct, elemental analysis of solid metals. More.
  • XRF instruments offer complete systems for the analysis of solids, liquids and powders. An XRD system integrated inside the same XRF instrument allows the determination of the phase content in many minerals and materials. More.
  • XRD systems provide cost-effective solutions for high-quality powder diffraction analyses and can also be a complementary technology to XRF spectrometry. More.

Food inspection: Enabling the highest levels of food safety, Thermo Fisher Scientific provides industry leading detection supported by unparalleled applications and global support.

Our integrated solutions maximize the probability of contamination detection and process accuracy at critical control points to support overall equipment effectiveness. Take a closer look!

Gauging

  • Li-Ion battery solutions: Our solutions enable customers to develop and manufacture advanced battery technology by providing real-time insights into the characteristics of electrode coating and separator film production to support the delivery of safe and effective batteries to market. More.
  • Food packaging: Through our in-line thickness and basis weight measurement solutions, we enable our customers to improve the quality and performance of food packaging materials. Our instruments provide precise measurement and process control as well as intuitive data insights to produce aseptic packaging through safeguarded measurement of barrier layers and automatic profile control in multi-layer applications. More.
  • Metals gauging: Through our in-line non-contact thickness and coating weight measurement solutions, we enable our customers to optimize quality and maximize productivity during high-speed production of steel plate and sheet. Our instruments provide precise real-time measurement and process control that meet the tightest specifications of any application, while maximizing raw material use, whether producing from iron ore or scrap or whether end products are several inches or less than a millimeter thick. More.

Material characterization:

  • Rheometers/viscometers: Our rheometers and viscometers are designed for easy and intuitive handling, intelligently guiding operators through all steps for failure-free measurement. Users can take advantage of enhanced useability and workflows enabled by “Connect Assist” technology as well as intuitive touch screen displays for easy visualization of measurement results directly from the instrument. They are designed to accurately measure the flow and deformation properties of fluids, semi-solids, and even solid materials - giving you the fast, repeatable data needed for today’s quality control, product development, and research applications. More.
  • Compounding/extrusion: Requiring only a small amount of material to conduct experiments, lab-scale extruders allow you to conduct numerous trials efficiently, cost effectively, all while conserving precious laboratory space. Our twin-screw extruders offer flexible configurations for small batches, ideally suited for pilot-scale production or low-volume manufacturing. Reliably scale-up and reduce time to market with the controlled, continuous processing of lab-scale extruders. More.

Process analyzers: Our slurry sampling, on-line particle & elemental analyzers solutions support you with accurate, real time & continuous data to ensure process control, automation, and optimization of minerals processing plants. Increased recovery, and reagent usage are enabled by dedicated analysis and representative sampling. 50 years of experience in mining solutions enable us to customize solutions – not just products – for our clients to solve their ongoing analytical challenges. Furthermore, our integrated solutions help contributing to the 2050 net zero target for decarbonization. Have a closer look!


Sponsored Content Policy: News-Medical.net publishes articles and related content that may be derived from sources where we have existing commercial relationships, provided such content adds value to the core editorial ethos of News-Medical.net, which is to educate and inform site visitors interested in medical research, science, medical devices and treatments.

Last updated: Nov 20, 2026 at 1:52 PM

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Thermo Fisher Scientific – Pharmaceutical and Biopharmaceutical Solutions. (2026, November 20). Why powder flowability matters in injectable implant manufacturing. News-Medical. Retrieved on November 20, 2026 from https://www.news-medical.net/whitepaper/20261120/Why-powder-flowability-matters-in-injectable-implant-manufacturing.aspx.

  • MLA

    Thermo Fisher Scientific – Pharmaceutical and Biopharmaceutical Solutions. "Why powder flowability matters in injectable implant manufacturing". News-Medical. 20 November 2026. <https://www.news-medical.net/whitepaper/20261120/Why-powder-flowability-matters-in-injectable-implant-manufacturing.aspx>.

  • Chicago

    Thermo Fisher Scientific – Pharmaceutical and Biopharmaceutical Solutions. "Why powder flowability matters in injectable implant manufacturing". News-Medical. https://www.news-medical.net/whitepaper/20261120/Why-powder-flowability-matters-in-injectable-implant-manufacturing.aspx. (accessed November 20, 2026).

  • Harvard

    Thermo Fisher Scientific – Pharmaceutical and Biopharmaceutical Solutions. 2026. Why powder flowability matters in injectable implant manufacturing. News-Medical, viewed 20 November 2026, https://www.news-medical.net/whitepaper/20261120/Why-powder-flowability-matters-in-injectable-implant-manufacturing.aspx.

Other White Papers by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.