DNBSEQ-G50 from MGI is a compact and flexible benchtop genetic sequencer. The two distinct Flow Cells provide flexibility and create a perfect balance between affordability and speed. Flow Cell Small (FCS) enables a short turnaround time for STAT samples.

Flow Cell Large (FCL) allows lower cost per sample. DNBSEQ-G50 provides around 3~4 read length options for both FCL and FCS, which aids an extensive range of research and clinical applications, such as targeted sequencing, low-pass whole genome sequencing, small whole genome sequencing, RNA sequencing, and whole exome sequencing, etc.

Features

  • Around 10~150 GB per run
  • Aids multiple read lengths, such as SE100, SE50, PE100, and PE150
  • Assists in sequencing applications for the clinic, research, agriculture, etc.
  • PE150 sequencing in just 40 hours

DNBSEQ-G50: Benchtop genetic sequencer

Image Credit: MGI

Performance parameter

Table 1. Source: MGI

DNBSEQ-G50
Flow Cell No. 1
Flow Cell Type FCS FCL
No. of Lanes per Flow Cell 1 lane
Effective Reads 100M 500M
Read Length SE100
PE100
PE150
SE50
SE100
PE100
PE150

 

* The maximum number of effective reads are based on the sequencing of an internal standard library. Actual output may vary with sample types and library preparation methods.

Table 2. Source: MGI

DNBSEQ-G50
Read Lengths Reads Data Output Q30 * Run Time**
SE50-FCL 500M ~25G >85% ~9 hrs
SE100-FCL 500M ~50G >85% ~13 hrs
PE100-FCL 500M ~100G >85% ~26 hrs
PE150-FCL 500M ~150G >80% ~40 hrs
SE100-FCS 100M ~10G >80% ~10 hrs
PE100-FCS 100M ~20G >85% ~20 hrs
PE150-FCS 100M ~30G >80% ~28 hrs

 

* The percentage of base above Q30 is the average of an internal standard library over the entire run. The actual performance is affected by factors such as sample type, library quality, and insert fragment length.
** Run time is calculated over the entire run including sample loading, sequencing, base calling, and data processing.

System parameter

Table 3. Source: MGI

. .
Operating Environment Requirements* Temperature: 19~25 °C
Relative Humidity: 20%RH ~ 80%RH, non-condensing
Atmospheric Pressure: 70 kPa ~ 106 kPa
Waterproof Rating: IPX0
Control Computer Configurations** CPU:  8th Gen Core i7 
Internal Storage: 32GB RAM 
HDD: ≥ 4TB 
Operating System: Windows 10 IOT (64-bit version)
Power & Dimensions & Net Weight Type: 100~240 V, 50/60 Hz
Rated Power: 900 VA
Dimensions: length: 654 mm; width: 489 mm; height: 545 mm
Net Weight: 85 kg
Product Model*** ****DNBSEQ-G50
****DNBSEQ-G50RS (for research only)
****DNBSEQ-G50CX (clinical purpose, overseas IVD)

 

Note:

*For indoor use only.  
**Support the computer’s configurations and system updates.
***means that “the product model names, DNBSEQ-G50 and  MGISEQ-200, are used in the selected oversea countries and China, respectively.”
****means that “*
Unless otherwise informed, StandardMPS and CoolMPS sequencing reagents, and sequencers for use with such reagents are not available in Germany, Spain, UK, Sweden, Belgium, Italy, Finland, Czech Republic, Switzerland, Portugal, Austria and Romania. Unless otherwise informed, StandardMPS sequencing reagents, and sequencers for use with such reagents are not available in Hong Kong."


*Unless otherwise informed, StandardMPS and CoolMPS sequencing reagents, and sequencers for use with such reagents, are not available in Germany, Spain, UK, Sweden, Belgium, Italy, Finland, Czech Republic, Switzerland, Portugal, Austria, and Romania. Unless otherwise informed, StandardMPS sequencing reagents, and sequencers for use with such reagents are not available in Hong Kong.

*Products are provided for Research Use Only. Not for use in diagnostic procedures (except as specifically noted).

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.