Background Noise in Western Blots

Western blot assays are a popular technique used to analyze protein expression by determining the molecular weight of proteins, their post-translational modifications, and their abundance.

Obtaining a good signal-to-noise ratio in western blotting is essentialSINITAR | Shutterstock

The key to a successful Western blot is achieving a signal to noise ratio allowing the detection of proteins while minimizing the background noise. High background noise can have several causes and associated solutions.

Detection Issues

Selecting the right antibody

A uniform high background is when the entire blot is darkened, which results in it being harder to see specific bands. Detection issues can be due to high concentrations of antibodies, which leads to saturation and coating of the membrane and thus nonspecific binding. This can be solved by reducing the antibody concentration via a dot-blot test to find the optimal antibody concentration.

Exposure time

Another problem related to detection issues that can lead to high uniform background noise is when the membrane is overexposed. If the exposure times are increased, it can enhance the overall background without increasing the sensitivity. This can be fixed by adjusting the exposure parameters and using a shorter exposure time.

Selecting a good quality membrane

Other solutions include loading more proteins, with the aim of increasing the target antigen’s abundance, titrating the primary antibody well and trying a different primary antibody if there are several alternatives available.

Other issues may be caused by the membrane itself. Certain membranes are considered to give more background noise than others. For example, nitrocellulose membranes are generally thought to give less background than polyvinylidene difluoride membranes(PVDF). However, PVDF membranes have a high binding capacity, while nitrocellulose membranes tend to be brittle and often do not bind smaller proteins.

Membrane selection should be done based on empirical data for each antigen-antibody combination. Furthermore, a dried out or old membrane that has passed its expiration date can contribute to high background.

Antibody storage

Sometimes, the binding activity of the antibody can be insufficient. This generally occurs if the handling and storage of antibodies was inappropriate. For example, thawing and repeatedly freezing antibodies should be avoided.

Each time a Western blot is prepared, a fresh aliquot of antibody that has been stored at -20 °C should be used. If antibodies are to be stored for long periods, it is recommended that they be stored at -80 °C to remain stable.

Blocking Issues

Uniform high background can also be caused by blocking issues, specifically insufficient blocking of the membrane.

Membrane blocking stops nonspecific binding of the antibody to the membrane and is done by incubating the blot with a blocking buffer. As such, both the temperature and length of the incubation can affect the success of membrane blocking and both can be increased in the event of insufficient membrane blocking.

Standard blocking is done for 1 hour at room temperature with agitation, or overnight at 4°C with agitation. Furthermore, the type and concentration of blocking reagent can affect its success. The type of blocking reagent to use depends on the interaction between the antigen and antibody, but a common initial choice is non-fat dry milk.

Typically, it is recommended to start at 1% or 5% concentrations of milk. If the antibody or detection system is incompatible with milk, 3% bovine serum albumin (BSA) is often used.

Another blocking issue that can lead to uniform high background are reactions between blocking agents and antibodies, resulting in interference. If the blocking agent is protein based, antibodies can bind to those proteins and cause high uniform background. For example, animal serum with unpurified primary antibodies can bind to animal proteins in blocking reagents.

As mentioned previously, certain blocking reagents are unsuitable for certain detection systems – milk contains biotin, and can react with avadin when an avadin-biotin detection system is used. If neither non-fat dry milk nor bovine serum albumin are suitable, protein-free or non-animal protein blocking reagents are available from some retailers. Alternatively, a secondary control lacking primary antibody can be run.

Contamination issues

Lastly, contamination can cause high background in Western blot assays. Contamination can occur when blocking solutions are reused, which they should never be. An alternative is to use pure protein as a blocking agent. Furthermore, buffers which contain detergent and milk can promote bacterial growth and should, therefore, be made fresh to avoid bacterial contamination.

Further Reading

Last Updated: Apr 5, 2019

Sara Ryding

Written by

Sara Ryding

Sara is a passionate life sciences writer who specializes in zoology and ornithology. She is currently completing a Ph.D. at Deakin University in Australia which focuses on how the beaks of birds change with global warming.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Ryding, Sara. (2019, April 05). Background Noise in Western Blots. News-Medical. Retrieved on November 13, 2024 from https://www.news-medical.net/life-sciences/Background-Noise-in-Western-Blots.aspx.

  • MLA

    Ryding, Sara. "Background Noise in Western Blots". News-Medical. 13 November 2024. <https://www.news-medical.net/life-sciences/Background-Noise-in-Western-Blots.aspx>.

  • Chicago

    Ryding, Sara. "Background Noise in Western Blots". News-Medical. https://www.news-medical.net/life-sciences/Background-Noise-in-Western-Blots.aspx. (accessed November 13, 2024).

  • Harvard

    Ryding, Sara. 2019. Background Noise in Western Blots. News-Medical, viewed 13 November 2024, https://www.news-medical.net/life-sciences/Background-Noise-in-Western-Blots.aspx.

Comments

  1. Wende DeBray Davis Wende DeBray Davis United States says:

    So as a patient that received results that stated my value was High Background, how do I proceed? And does this mean my western blot was done incorrectly?

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Study highlights anti-inflammatory properties of herbal medicine, Erigeron breviscapus to treat osteoarthritis