MassTrak Steroid Serum RUO Sets for accurate clinical research measurements

The Waters MassTrak™ Steroid Serum RUO Sets support precise steroid measurement in clinical research, helping laboratories optimize method performance and achieve reliable, consistent results.

Designed to streamline laboratory workflows, these comprehensive sets include calibrators and quality controls (QCs) traceable to National Institute of Standards and Technology (NIST) certified reference material (CRMs), along with internal standards and an optimization mix. By eliminating the need for in-house preparation, the sets help laboratories save valuable time and resources while supporting consistent analytical performance.

Overview

  • Comprehensive, Ready-to-Use Standards: MassTrak Steroid Serum RUO Sets provide essential standards for laboratory-developed test (LDT) development, including calibrators, QCs, internal standards, and an optimization mix, helping streamline workflows and reduce preparation time.
  • Traceability and Quality: Calibrators traceable to NIST CRMs and reference measurement procedures, along with quality controls, support laboratories in meeting applicable ISO 15189 requirements.
  • Flexible Method Development: Broad, customer-informed analyte concentration ranges, combined with a flexible design featuring 7+1 calibrator levels and four QC levels, enable laboratories to tailor methods to their specific LDT requirements.
  • Consistent Analytical Performance: High lot-to-lot manufacturing consistency and standardized value assignment support reliable LC-MS/MS method performance and comparability across laboratories. 
  • Extended Stability and Cost Efficiency: Extended shelf life and in-use stability support prolonged product use, helping laboratories minimize reagent costs per batch when following RUO steroid analysis methods described in the Waters Application Note library. 

MassTrak Steroid Serum Calibrator and QC Sets (RUO)

Product Description Format In-use stability Shelf life
MassTrak Steroid Serum Calibrator Set 1 (RUO) 12 lyophilized steroid analytes 7 x 2 mL (Reconstitution volume) 3 months at or below -10 °C; 1 month at 2–8 °C 3 years at or below -10 °C
MassTrak Steroid Serum QC Set 1 (RUO) 12 lyophilized steroid analytes 3 x 2 mL (Reconstitution volume) 3 months at or below -10 °C; 1 month at 2–8 °C 3 years at or below -10 °C
MassTrak Steroid Serum Calibrator Set 2 (RUO) 4 lyophilized steroid analytes 8 x 2 mL (Reconstitution volume) 3 months at ≤ -10 °C; 1 month at 2–8 °C 3 years at ≤ -10 °C
MassTrak Steroid Serum QC Set 2 (RUO) 4 lyophilized steroid analytes 4 x 2 mL (Reconstitution volume) 3 months at ≤ -10 °C; 1 month at 2–8 °C 3 years at ≤ -10 °C
MassTrak Steroid Serum Calibrator Set 3 (RUO) 5 lyophilized steroid analytes 8 x 2 mL (Reconstitution volume) 3 months at ≤ -10 °C; 1 month at 2–8 °C 3 years at ≤ -10 °C
MassTrak Steroid Serum QC Set 3 (RUO) 5 lyophilized steroid analytes 4 x 2 mL (Reconstitution volume) 3 months at ≤ -10 °C; 1 month at 2–8 °C 3 years at ≤ -10 °C
MassTrak Steroid Serum Internal Standards (RUO) 12 lyophilized steroid analytes 1 x 25 mL (Reconstitution volume) 3 months at ≤ -10 °C 1.5 years at ≤ -10 °C
MassTrak Steroid Serum optimization mix (RUO) 12 lyophilized steroid analytes 1 x 2 mL (Reconstitution volume) 3 months at ≤ -10 °C 1.5 years at ≤ -10 °C

Support Accurate Steroid Quantification with MassTrak Serum Calibrator Sets (RUO)

Waters MassTrak Steroid Serum Calibrator Sets 1, 2, and 3 (RUO) support accurate and reliable steroid quantification  in human serum for clinical research applications. Featuring broad, customer-informed analyte concentration ranges, these sets offer flexibility to meet diverse laboratory method development needs.

Calibrators are traceable to NIST CRMs and applicable reference measurement procedures, including those established by RfB (Germany) and the University of Ghent, for specific analytes.

MassTrak Steroid Serum Calibrator Set 1 (RUO) includes 12 lyophilized steroid analytes with 7 x 2 mL reconstitution volume. Designed for extended usability, the set offers:

  • Shelf Life: Three years when stored at ≤-10 °C.
  • In-Use Stability: Three months at ≤-10 °C or one month at 2-8 °C.

Source: Waters Advanced Diagnostics 

MassTrak Steroid Serum Calibrator Set 1 contains 12 lyophilized steroid analytes with 7 x 2 mL reconstitution volume. Shelf life is 3 years at ≤-10 °C and in-use stability is 3 months at ≤-10 °C ; 1 month at 2-8 °C.

MassTrak Steroid Serum Calibrator Set 2 (RUO) includes four lyophilized steroid analytes with 8 x 2 mL reconstitution volume. Designed for extended usability, the set offers:

  • Shelf Life: Three years when stored at ≤-10 °C.
  • In-Use Stability: Three months at ≤-10 °C or one month at 2-8 °C.

Source: Waters Advanced Diagnostics 

MassTrak Steroid Serum Calibrator Set 2 contains 4 lyophilized steroid analytes with 8 x 2 mL reconstitution volume. Shelf life is 3 years at ≤-10 °C and in-use stability is 3 months at ≤-10 °C ; 1 month at 2-8 °C.

MassTrak Steroid Serum Calibrator Set 3 (RUO) includes five lyophilized steroid analytes with 8 x 2 mL reconstitution volume. Designed for extended usability, the set offers:

  • Shelf Life: Three years when stored at ≤-10 °C.
  • In-Use Stability: Three months at ≤-10 °C or one month at 2-8 °C.

Source: Waters Advanced Diagnostics 

MassTrak Steroid Serum Calibrator Set 3 contains 5 lyophilized steroid analytes with 8 x 2 mL reconstitution volume. Shelf life is 3 years at ≤-10 °C and in-use stability is 3 months at ≤-10 °C ; 1 month at 2-8 °C.

Ensure Consistent Analytical Performance with MassTrak Steroid Serum QC Sets 

Waters MassTrak Steroid Serum QC Sets 1, 2, and 3 (RUO) support reliable and consistent steroid measurement in clinical research applications. Manufactured with high lot-to-lot consistency, these quality control sets are traceable to NIST CRMs and applicable reference measurement procedures, including those established by RfB (Germany) and the University of Ghent for specific analytes.

Quality control concentration values are informed by customer feedback, Endocrine Society guidelines, and the CDC Newborn Screening Quality Assurance Program (NSQAP), supporting diverse laboratory research needs. 

MassTrak Steroid Serum QC Set 1 (RUO) includes 12 lyophilized steroid analytes with a reconstitution volume of 3 x 2 mL. Designed for extended usability, the set offers:

  • Shelf Life: Three years when stored at ≤-10 °C.
  • In-Use Stability: Three months at ≤-10 °C or one month at 2-8 °C.

Source: Waters Advanced Diagnostics  

MassTrak Steroid Serum QC Set 1 contains 12 lyophilized steroid analytes with 3 x 2 mL reconstitution volume. Shelf life is 3 years at ≤-10 °C and in-use stability is 3 months at ≤-10 °C ; 1 month at 2-8 °C.

MassTrak Steroid Serum QC Set 2 (RUO) includes 4 lyophilized steroid analytes with a reconstitution volume of 4 x 2 mL. Designed for extended usability, the set offers:

  • Shelf Life: Three years when stored at ≤-10 °C.
  • In-Use Stability: Three months at ≤-10 °C or one month at 2-8 °C.

Source: Waters Advanced Diagnostics  

MassTrak Steroid Serum QC Set 2 contains 4 lyophilized steroid analytes with 4 x 2 mL reconstitution volume. Shelf life is 3 years at ≤-10 °C and in-use stability is 3 months at ≤-10 °C ; 1 month at 2-8 °C.

MassTrak Steroid Serum QC Set 3 (RUO) includes 5 lyophilized steroid analytes with a reconstitution volume of 4 x 2 mL. Designed for extended usability, the set offers:

  • Shelf Life: Three years when stored at ≤-10 °C.
  • In-Use Stability: Three months at ≤-10 °C or one month at 2-8 °C.

Source: Waters Advanced Diagnostics  

MassTrak Steroid Serum QC Set 3 contains 5 lyophilized steroid analytes with 4 x 2 mL reconstitution volume. Shelf life is 3 years at ≤-10 °C, with in-use stability of 3 months at ≤-10 °C ; 1 month at 2-8 °C.

Internal Standards and Optimization Mix for Steroid LC-MS/MS Methods

Waters MassTrak Steroid Serum Internal Standard and Optimization Mix (RUO) provides high-purity, lyophilized labeled and non-labeled standards designed to support reliable method development and optimization in clinical research. Intended for use alongside MassTrak Steroid Serum Calibrators and Quality Controls, these products help laboratories streamline workflows and achieve consistent analytical performance. 

MassTrak Steroid Serum Internal Standards (RUO) includes 12 lyophilized steroid analytes: 13C3-androstenedione, 2H4-corticosterone, 13C3-cortisol, 13C3-11-deoxycorticosterone, 13C3-11-deoxycortisol, 2H4-21-deoxycortisol, 13C3-DHEA, 2H6-DHEAS, 13C3-dihydrotestosterone, 13C3-17-hydroxyprogesterone, 13C3-progesterone, and 13C3-testosterone.

MassTrak Steroid Serum Optimization Mix (RUO) includes 12 lyophilized steroid analytes: androstenedione, corticosterone, cortisol, 11-deoxycorticosterone, 11-deoxycortisol, 21-deoxycortisol, DHEA, DHEAS, dihydrotestosterone, 17-hydroxyprogesterone, and progesterone.

MassTrak Steroid Calibrator Set to establish points of reference in LC-MS/MS systems for steroid analysis and MassTrak Steriod Quality Control Set to monitor performance of clinical LC-MS/MS systems for steroid analysis.

MassTrak Steroid Calibrator Set (RUO) to establish points of reference in LC-MS/MS systems for steroid analysis, and MassTrak Steroid Quality Control Set (RUO) to monitor performance of clinical LC-MS/MS systems for steroid analysis. Image Credit: Waters Advanced Diagnostics 

MassTrak Steroid Serum family displaying Calibration, Quality control, Optimization mix and Internal standard sets.

MassTrak Steroid Serum Sets (RUO) displaying Calibration, Quality Control, Optimization Mix, and Internal Standard Sets. Image Credit: Waters Advanced Diagnostics 

To account for sample matrix effects in LC-MS/MS assays for steroids.

MassTrak Steroid Internal Standard (RUO) help compensate for sample matrix effects in steroid LC-MS/MS assays. Image Credit: Waters Advanced Diagnostics 

Optimization of LC-MS/MS steroid method parameters.

MassTrak Steroid Optimization Mix supports the optimization of LC-MS/MS method parameters for steroid analysis. Image Credit: Waters Advanced Diagnostics 

Waters, Xevo™, MassTrak™, ACQUITY™, and UPLC™ are trademarks of Waters Corporation or its affiliates 

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.