Introduction
How Photothermal IR and SRS Imaging Work
Biological Applications and Emerging Opportunities
The Multimodal Turn: Combining Chemical and Fluorescence Imaging
Practical Limitations and Future Directions
Closing Perspective
References and Further Reading
Photothermal infrared and stimulated Raman scattering microscopy reveal the chemical composition of biological specimens without conventional fluorescent labels. Advances in expansion microscopy, artificial intelligence, and multimodal imaging are enhancing spatial resolution and molecular characterization.
Image credit: Heiti Paves/Shutterstock.com
Introduction
Fluorescence microscopy has become a fundamental tool in biological research because it enables visualization of specific cellular processes, proteins, and organelles with high spatial resolution and sensitivity. However, fluorescence imaging usually uses fluorescent dyes, antibodies, or genetically marked fluorescent proteins to identify molecular targets of interest. These labels may hamper the normal functioning of the investigated biological system by altering the localization and activity of the molecular target. Fluorescent signals may also undergo photobleaching during repeated illumination, while overlapping emission spectra can complicate the simultaneous detection of multiple targets.2,3
Label-free chemical imaging offers another method for detecting the intrinsic molecular properties of a biological specimen without introducing a marker. Vibrational spectroscopy-based techniques characterize molecular composition through bond vibrations. Proteins, lipids, nucleic acids, and metabolites contain chemical bonds that produce characteristic vibrational signatures, although some molecules may share similar spectral features. This gives researchers the ability to investigate biochemical organization in cells and tissues while minimizing the negative effects of the applied labeling. However, label-free imaging does not necessarily provide the same target specificity as antibody-based fluorescence detection.1,2,3
Recent developments in photothermal infrared (IR) microscopy and stimulated Raman scattering (SRS) microscopy have improved the sensitivity, spatial resolution, and acquisition speed of vibrational imaging.1,2,3
How Photothermal IR and SRS Imaging Work
Photothermal IR and SRS microscopy detect molecular vibrations through different mechanisms, providing chemical contrast without conventional fluorescent labels. Photothermal IR microscopy measures the heat generated when biological samples absorb mid-infrared radiation at specific vibrational frequencies. This absorption produces localized temperature changes that alter the sample's refractive index, allowing a visible-light probe beam to detect the resulting changes and generate chemical contrast. The resulting signals generate spatial maps of chemical composition. Photothermal detection improves spatial resolution compared with conventional IR absorption microscopy, enabling submicron imaging. However, strong water absorption can restrict imaging depth in hydrated tissues, making sample thickness and water content important considerations.2
SRS microscopy uses synchronized pump and Stokes laser beams to probe molecular vibrations. When the frequency difference between these beams matches a molecular vibrational frequency, energy is transferred from the pump beam to the Stokes beam, producing measurable intensity changes known as stimulated Raman loss and stimulated Raman gain, respectively. By detecting these changes, SRS microscopy can map the spatial distribution of specific chemical bonds more rapidly than spontaneous Raman microscopy, while avoiding the characteristic nonresonant four-wave-mixing background associated with coherent anti-Stokes Raman scattering (CARS).1,2
Despite their different detection mechanisms, photothermal IR and SRS microscopy complement one another in characterizing biological specimens. This complementarity arises because infrared absorption is sensitive to changes in molecular dipole moment, whereas Raman scattering depends on changes in molecular polarizability, allowing the two techniques to probe different aspects of molecular composition.2
Biological Applications and Emerging Opportunities
SRS microscopy is particularly useful for studying lipid metabolism because lipid molecules contain abundant carbon-hydrogen bonds that produce strong vibrational signals. Researchers have used SRS to visualize lipid droplets in living cells and monitor lipid storage and mobilization in real time, providing insights into metabolic changes relevant to obesity, metabolic disorders, and cellular energy regulation.2
SRS enables the determination of protein distribution without direct use of labels through the vibration signals produced by proteins themselves. Chan et al. reviewed Vibrational Imaging of Swelled Tissues and Analysis (VISTA), which combines expansion microscopy with SRS to improve effective spatial resolution. The method achieved an effective spatial resolution of approximately 78 nm in expanded HeLa cells, revealing endogenous protein distributions during cell division. In contrast to conventional approaches to imaging, the VISTA method is able to visualize the structures of the mouse brain, such as dendritic spine heads and synapses.1
Another application involves distinguishing tumor tissues from healthy tissues based on biochemical composition. The differences in the signals from lipids and proteins allow for the characterization of tissue heterogeneity and metabolism of tumors; however, there is still a need for additional validation to use the method in broader diagnostics.1,3
Papillary Renal Cell Carcinoma classified by IR Spectral Pathology | Cancer Detection
Video credit: Bruker/Youtube.com
The Multimodal Turn: Combining Chemical and Fluorescence Imaging
Although label-free imaging provides information on endogenous chemical composition, fluorescence microscopy remains the main approach for identifying molecular targets. Fluorescence microscopy combines high sensitivity and high molecular specificity through fluorescently labeled antibodies, dyes, and proteins. Label-free vibrational imaging provides broader information on the sample's chemical composition and does not require labeling each molecular species. Small vibrational probes, such as alkyne and carbon-deuterium bonds, can further enhance chemical specificity and multiplexing, although their introduction means that such approaches are not strictly label-free.2,3,4
The integration of SRS and fluorescence microscopy illustrates the potential of this approach. In the VISTA platform, SRS imaging coupled with immunofluorescence is used to study the same biological material. The SRS signals that do not involve any labels help determine the chemical properties associated with the protein, while immunofluorescence identifies specific protein targets recognized by antibodies. This combination allows researchers to correlate chemical distributions with established biological markers and improve the interpretation of tissue structures.1
Chan et al. described the application of VISTA imaging to the amyloid-beta plaques of 5xFAD mouse models of Alzheimer's disease. The approach resolved different plaque structures, including dense protein aggregate cores and peripheral filaments. When correlated with immunofluorescence, these observations revealed associations between plaque ultrastructure and reactive astrocyte morphology, providing additional information about the neuroinflammatory environment.1
Multimodal imaging nevertheless requires careful coordination of image acquisition, spatial registration, and data interpretation. Differences in resolution, contrast mechanisms, and sample preparation can complicate comparisons between imaging datasets. Therefore, integrating multiple modalities is most useful when the biological question requires complementary information that cannot be obtained adequately through a single technique.1,4
Practical Limitations and Future Directions
Though technological advancements have emerged, there are several challenges that hinder the broader use of label-free chemical imaging. One such hurdle is the complex nature and cost of instruments where synchronization of lasers, special optics, and sensitive detectors may be required. In addition, photothermal IR microscopy also relies on controlled sample conditions because water absorption and sample thickness affect the detected signal. Similarly, SRS measurements depend on adequate signal strength and appropriate spectral selection to distinguish molecular components.1,2
Biological samples contain many vibrating molecules, making it difficult to differentiate components with a limited number of spectral readings. Numerous computational techniques, such as artificial intelligence and machine learning, are used to separate spectra, minimize signal noise, identify patterns, and segment images based on identification results. However, limited training datasets, poor generalizability across experimental conditions, and the lack of standardized validation procedures remain important challenges.1,3
Sample preparation and spatial resolution also require consideration. Expansion microscopy, which physically enlarges biological specimens using swellable hydrogels, has emerged as a strategy for improving the effective resolution of chemical imaging. Chan et al. described how combining expansion microscopy with SRS can improve effective spatial resolution from approximately 300 nm to 50–78 nm, depending on the expansion factor. However, expansion requires substantial specimen preparation and is therefore unsuitable for directly monitoring ongoing biological processes in living cells. Hydrogel-derived background signals and the retention of endogenous biomolecules must also be considered when interpreting chemical measurements.1
Future advancements will likely focus on improving detection sensitivity, streamlining equipment, and standardizing analytical processes. Smaller optical systems, better spectral processing, and integrated microscopy systems might increase availability. Nevertheless, additional validation is needed to establish reproducibility across different biological specimens, particularly complex tissues and clinical samples. Improved computational registration and data management will also be important as multimodal imaging generates increasingly large and complex datasets.1,2,3
Download your PDF copy by clicking here.
Closing Perspective
Photothermal IR and SRS microscopy detect chemical signatures without conventional fluorescent labeling, offering opportunities to investigate lipid metabolism, protein distribution, cellular heterogeneity, and tissue characteristics. Advances in expansion microscopy and computer analysis techniques furthermore enhance the capability of these methods in providing a high-resolution molecular map of samples.1,2,3
However, label-free chemical imaging is not a universal replacement for fluorescence microscopy. Each method provides different data about samples, and its applicability depends on the biological question, sample properties, and the need for specificity. The combination of fluorescence and vibrational imaging is useful for exploring biology because the acquisition and spatial correlation of complementary information can provide a more complete picture of the biological specimen. The future of biological microscopy will therefore likely depend on the thoughtful integration of chemical and molecular imaging approaches rather than the dominance of any single technology.1,2,3,4
References and Further Reading
- Chan, Y. H., Hibbard, M. C., & Gao, R. (2026). High-resolution molecular mapping by expansion-coupled label-free and multimodal imaging. Current Opinion in Chemical Biology. 93, 102715. DOI: 10.1016/j.cbpa.2026.102715, https://www.sciencedirect.com/science/article/pii/S1367593126000645
- Hu, F. (2025). Vibrational probes in bioimaging and chemical biology. Chemical & Biomedical Imaging. 3, 784–786. DOI: 10.1021/cbmi.5c00107, https://pubs.acs.org/doi/10.1021/cbmi.5c00107
- Cui, Y., Zhang, Z., Shi, Y., & Hu, Y. (2025). Chemical imaging for biological systems: Techniques, AI-driven processing, and applications. Journal of Materials Chemistry B. 13(24). 6916–6948. DOI: 10.1039/D4TB02876G, https://pubs.rsc.org/en/content/articlelanding/2025/tb/d4tb02876g
- Wu, M., & Shu, J. (2018). Multimodal molecular imaging: Current status and future directions. Contrast Media & Molecular Imaging. 2018, Article ID 1382183. DOI: 10.1155/2018/1382183, https://onlinelibrary.wiley.com/doi/10.1155/2018/1382183
Last Updated: Nov 24, 2026