The Atellica DT 250 Analyzer integrates reliable and established Syva EMIT technologies with the practicality and dependability required to satisfy the rigorous demands of contemporary drug-testing facilities.
Benefits
Reliable, practical design
Achieve greater power within a compact footprint—a small benchtop system that provides the throughput and onboard sample capacity that was once exclusive to larger, floor-standing models.
- Take advantage of a user-friendly, dependable, and exceptionally efficient tool that can be operated effortlessly and confidently by personnel of varying skill levels.
- Enhance workflow and minimize hands-on time with a capacity of 225 tests per hour, 23 dual-reagent capability, and an onboard capacity for 95 barcoded samples.
- Achieve increased testing versatility with a distinctive system that accommodates up to three reagents and features 10 open channels.
Intelligent navigation
Accelerate results with user-friendly software designed to decrease operational mistakes and reduce manual effort.
- Enhance operational efficiency through user-friendly flags that notify operators of necessary actions.
- Store reagents onboard even when the analyzer is turned off, utilizing a separate power source for the cooling unit.
- Oversee inventory management on-screen with real-time monitoring of the availability of onboard reagents.
- Ensure the secure and smooth transfer of results to the LIS.
Secure operation
A collection of cybersecurity functionalities designed to assist in upholding the advised security standards of the device, providing integrated security measures that are crucial for contemporary laboratory and drug testing settings.
- Have assurance in the protection of patient information through a system that adheres to existing security and industry privacy standards.
- Safeguard outcomes and guarantee secure functionality with password safeguards and hierarchical user access limited exclusively to authorized personnel.
- Minimize the likelihood of cyber threats by utilizing the most recent IT/software and cybersecurity capabilities, which encompass secure configurations, authentication, and data encryption.
Trusted EMIT technology
When the results of drug testing carry significant life-altering consequences, rely on Syva EMIT assays, a reputable brand in the field of drug testing since 1972.
- Have assurance in drug-testing outcomes with Syva EMIT reagents—recognized as one of the most commonly utilized and thoroughly validated reagents in the field.
- Syva products boast a significant international presence and are available globally.
- Utilizing Syva assays allows one to confidently broaden the drug-testing services to include drugs-of-abuse, specimen validity assessments, as well as therapeutic and immunosuppressant drug monitoring.
Comprehensive menu
The Atellica DT 250 Analyzer provides one of the most extensive IA menus available in the market, featuring urine, serum toxicology, and specimen validity testing.
- A comprehensive portfolio of high-performing assays is available, featuring the largest Drug Abuse Testing (DAT) menu, including five specimen validity tests, in the industry.
- This portfolio provides the flexibility to tailor the assay menu according to customer requirements, encompassing a wide range of drugs of abuse, therapeutic drug monitoring, and immunosuppressant drug-testing assays.
- There is no need for sample preparation with liquid; ready-to-use reagents are provided.
- Various kit sizes and extensive cross-reactivity profiles are available to meet all testing volumes and settings.
Assays
A comprehensive menu covering drugs of abuse/toxicology, therapeutic drug monitoring, and specimen validity testing.
Comprehensive portfolio of assays
Drugs of abuse. Source: Siemens Healthineers
. |
. |
. |
. |
6-Acetylmorphine (6-AM) |
Amphetamines |
Barbiturates |
Benzodiazepines |
Benzodiazepines (High-sensitivity)*,† |
Buprenorphine |
Cannabinoids (THC) |
Cocaine Metabolite |
Ecstasy |
EDDP* |
Ethyl Alcohol |
Ethyl glucuronide (EtG)*,‡ |
Fentanyl* |
Hydrocodone*,§ |
Ketamine*,‡ |
Lysergic Acid Diethylamide (LSD) |
Meperidine*,‡,§§ |
Methadone |
Methamphetamine** |
Methaqualone |
Opiates |
Oxycodone |
Phencyclidine |
Propoxyphene |
Synthetic cannabinoids*,‡ |
Tramadol* |
Xylazine*,§,‡ |
|
Serum toxicology. Source: Siemens Healthineers
. |
. |
. |
. |
. |
Acetaminofen |
Barbiturates |
Benzodiazepines |
Salicylic Acid |
Tricyclic Antidepressants |
Specimen validity tests. Source: Siemens Healthineers
. |
. |
. |
. |
. |
Creatinine |
Nitrites |
Oxidants |
pH |
Specific Gravity |
Therapeutic drug monitoring. Source: Siemens Healthineers
. |
. |
. |
. |
Amikacin |
Caffeine |
Carbamazepine |
Cyclosporine |
Digoxin |
Disopyramide |
Ethosuximide |
Gabapentin§§ |
Gentamicin |
Lamotrigine§§ |
Levetiracetam§§ |
Lidocaine |
Methotrexate |
Mycophenolic Acid† |
N-Acetylprocainamide (NAPA) |
Phenobarbital |
Phenytoin |
Primidone |
Procainamide |
Quinidine |
Sirolimus |
Tacrolimus |
Theophylline |
Tobramycin |
Topiramate§§ |
Valproic Acid |
Vancomycin |
Voriconazole§§ |
Zonisamide§§ |
|
|
|
Technical details
Source: Siemens Healthineers
System |
|
Benchtop system with mounted computer (external barcode reader optional) |
Dimensions (without computer) |
Width: 880 mm (34.6 in) Depth: 700 mm (27.5 in) Height: 660 mm (25.9 in) |
Weight |
~95 kg (209 lb.) |
Water consumption |
Up to 1.5 L/h |
Capacity |
Onboard sample |
95 barcoded samples |
Open channels |
10 |
Throughput |
One reagent: 340 tests per hour Two reagents: 225 tests per hour Three reagents: 120 tests per hour |
Walkaway time |
3 hours (dependent on test mix) |
Sample and reagent handling |
Sample types |
Serum, plasma, urine, aqueous solution |
Sample volume |
2-200 μL |
Sample dilution |
Automatic pre- and post-dilution |
Sample containers |
Primary and secondary tubes, micro-cups for pediatric samples |
Time to first result |
As soon as 8 minutes |
Removable and interchangeable reagent tray |
Reagent capacity: 48 reagent positions or 23 dual-reagent methods (majority of EMIT) 24 positions for 30-mL, 24 positions for 15-mL spaces Two spaces for onboard cleaner |
Cuvettes |
80 PMMA reusable cuvettes onboard (in segments of five) 6 mm light path |
Operation |
Detection capabilities |
Clot detection, crash and collision detection |
Reaction temperature |
37 °C ± 0.1 °C |
Photometric range |
-0.1 to 3.6 |
Optical resolution |
0.001 ABS |
Interferential optical filters (340-750 nm) |
12 |
Inventory management |
|
Off-screen inventory management with real-time tracking of onboard reagent availability |