Simplified model for describing biological tissue properties allows time and cost savings

NewsGuard 100/100 Score

Viscous mechanical properties of biological tissues can now be described more easily than before. This is shown by a recently published paper of a team of the Karl Landsteiner University of Health Sciences Krems. The team demonstrates that an established mathematical model for soft biological tissues can be greatly simplified, allowing extensive time and cost savings.

Whether a tissue is diseased or healthy can often be diagnosed on the basis of its mechanical properties – if these are known, described appropriately and compared objectively. Mathematical constitutive models have been developed precisely for this purpose. They have proven themselves in practice but require extensive lab measurements and calibrations. A team from the Division of Biomechanics at Karl Landsteiner University of Health Sciences Krems (KL Krems) has now succeeded in radically simplifying an accepted model from the literature, thus enabling future time and cost savings in tissue characterization.

Hard facts for soft tissue

The team, led by biomechanics professor and study director Dieter Pahr, tackled the "Adaptive Quasi-Linear Viscoelastic (AQLV) Model". This model describes properties of soft biological tissues, taking into account complex mechanisms under variable mechanical stress (tensile forces). In principle, this model is very flexible, since it applies to different load levels, but this flexibility comes at a high price, as Dieter Pahr explains: "The more flexible a mathematical model, the more material parameters have to be determined in the lab. In addition, as the number of parameters increases, comparability between different tissues becomes increasingly difficult. That's why we took another closer look at the existing AQLV model."

And in fact, the team succeeded in drastically reducing the parameters required for the model in an elaborate experimental work. In the traditional model the tissue to be examined is divided (mathematically) into three layers which have to be calibrated. This requires four loading experiments (incremental ramp-holding) for calibration in every case.

In practice, a total of 19 parameters thus have to be calculated in order to set up the model correctly. We now have been able to reduce this to eight, which in the experiments allows for a time saving of 50 percent."

Dieter Pahr, Biomechanics Professor and Study Director

Sophisticated experiments

The studies were carried out on pig muscle and liver, which are established experimental models. The team also benefited from the excellently equipped biomechanics laboratory at KL (Core Facility at Campus Krems) which focuses on the characterization of material properties of biological tissues in many different research projects. This project in particular was realized in cooperation with ACMIT GmbH in Wiener Neustadt and supported by the FTI funding programme of the province of Lower Austria. Thus, the Division of Biomechanics at KL is considered a leader in the assessment of bone properties, 3D printing of artificial biological tissues and the production of artificial organs for medical training purposes in Lower Austria.

Against the background of this extensive practical and experimental experience of his team, Pahr says: "Of course, the original AQLV model with its many parameters is well suited to make statements under certain circumstances. But in everyday medical or scientific practice, it often has to be considered whether the informative value thus obtained justifies the effort required. If it doesn’t, then the model we propose is a real asset in many cases." The paper now published in the Journal of the Mechanical Behaviour of Biomedical Materials thus once again reflects the approach of research at KL Krems in the field of medical technology, which focuses on application-oriented findings with real benefits for clinical research.

Source:
Journal reference:

Aryeetey, O.J., et al. (2022) A parameter reduced adaptive quasi-linear viscoelastic model for soft biological tissue in uniaxial tension. Journal of the Mechanical Behavior of Biomedical Materials. doi.org/10.1016/j.jmbbm.2021.104999.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
New research pinpoints key pathways in prostate cancer's vulnerability to ferroptosis