To monitor heart rhythms and muscle function, doctors often attach electrodes to a patient's skin, detecting the electrical signals that lie beneath. These impulses are vital to the early diagnosis and treatment of many disorders, but currently available electrodes have limited function or are expensive to manufacture. Researchers reporting in ACS Nano, however, have now developed a low-cost, spongy version with improved signal detection that's made with a surprising template -; a sugar cube.

The current gold-standard electrodes for electrophysiologic monitoring rely on a silver disc that contacts the skin through a conductive gel. These electrodes are critical tools for detecting abnormal electrical signals linked to health issues, such as heart attacks, brain disorders or neuromuscular diseases. These devices are not without their drawbacks, however. They are rigid and cannot conform well to the skin, particularly when the patient is physically active, reducing signal quality. In addition, the conductive gel dries quickly, preventing long-term monitoring and rare-event detection. Addressing these challenges, researchers have designed soft electrodes that better conform to the skin, as well as microneedle-based versions that physically penetrate the skin, but these are expensive to manufacture, limiting their widespread use. So, Chuan Wang and colleagues wanted to develop a low-cost sponge-like electrode that would offer more consistent and resilient skin contact.

To make the new device, researchers started with commercially available sugar cubes, which they molded into a template that was dipped into liquid polydimethylsiloxane (PDMS). The PDMS became a solid structure after a curing step. They then dissolved the sugar with hot water and coated the sponge's micropores with a conductive thin film to form the electrode.

Because the micropores allowed the spongy material to have increased contact area with the skin, the new device showed strong signal intensity and reduced noise when compared with standard electrodes. The micropores also helped the device carry more conductive gel, which kept them from drying out as quickly and losing signal, compared to standard versions. The gel also acted as a shock absorber, reducing the negative impacts of patient movement on skin-electrode contact and ensuring signal detection. The researchers tested the ability of the sponge device to monitor uterine contractions during labor and found it performed as well as, or better than, a conventional electrode. As a low-cost, flexible alternative, sponge electrodes expand the possibilities for wearable health care applications, including use in medical exams that require patients to move, or for long-term monitoring of people at home or at work, say the researchers.

Source:
Journal reference:

Lo, L-W., et al. (2022) Stretchable Sponge Electrodes for Long-Term and Motion-Artifact-Tolerant Recording of High-Quality Electrophysiologic Signals. ACS Nano. doi.org/10.1021/acsnano.2c04962.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Placental DNA methylation patterns altered by pregnancy air pollution exposure, research reveals