Lunatic is a UV/Vis spectrophotometer engineered for precise microvolume quantification of proteins and nucleic acids.

The instrument provides the functionality of a general-purpose UV/Vis spectrophotometer, but is specifically optimized for high-throughput, low-volume UV/Vis absorbance data. It can analyze samples as small as 2 µL, accommodating up to 96 wells in an SBS-format plate.

Lunatic accurately quantifies proteins, DNA, and RNA within minutes, determining both concentration and purity without requiring dilutions or additional preparation.

  • Protein quantification: The spectrophotometer measures protein concentration across an extensive range of 0.03–275 mg/mL, using full-spectrum UV/Vis data. This capability is well-suited for formulation, conjugation, and purity assessments
  • Nucleic acid concentration: DNA or RNA can be quantified with precision over the range of 1.5–13,750 ng/µL without the need for dilutions. This is essential for genomics workflows and quality control.
  • Contaminant detection: Impurities such as buffer components or co-purified proteins can be identified and quantified using Unmix deconvolution algorithms, ensuring the reliability and cleanliness of results.

Lunatic for low-volume UV/Vis analysis

Image Credit: Unchained Labs

Capabilities

User-friendly workflow

Three-step workflow for Lunatic

Image Credit: Unchained Labs

Lunatic offers highly precise UV/Vis quantification for microvolume samples. This system combines fixed pathlength measurements with a broad dynamic range, ensuring consistent and accurate concentration data for various biomolecules.

Eliminate the need for sample preparation, cleaning, and concerns about cross-contamination or evaporation, and enjoy samples that remain stable for up to two hours.

Lunatic processes 96 samples in just 10 minutes, and each microfluidic circuit incorporates two built-in fixed path lengths, enabling a wide dynamic range from 0.03 to 275 OD. Simply load samples and obtain exceptional results.

Max out the biologic

Lunatic for low-volume UV/Vis analysis

Image Credit: Unchained Labs

Lunatic stands out as the sole UV/Vis spectrophotometer capable of high-throughput, high-concentration measurement of biologics. Its dynamic range extends from 0.02 mg/mL to 200 mg/mL (mAb), allowing analysis of any protein without dilution. This eliminates the inefficiency of processing single proteins sequentially and the subsequent cleanup.

Ridiculously good data

Graph showing known concentration (x) against measured concentration (y). R = 0.999

Image Credit: Unchained Labs

Source: Unchained Labs

Known Conc. (mg/mL) Average Conc. (mg/mL) CV (%)
201.4 201.7 0.7%
169.9 171.1 0.7%
139.4 140.7 0.4%
113.1 115.0 0.6%
79.4 80.7 0.2%
50.2 51.2 0.2%
19.9 20.3 0.3%
12.1 12.2 0.2%
7.21 7.28 0.2%
2.35 2.37 0.2%

Achieve precise measurements within 1% and accuracy within 2%. By utilizing two fixed path lengths, Lunatic delivers outstanding data for both low and high protein concentrations, consistently yielding expected concentrations. With its minimal sample volume requirement, superior throughput, and remarkably accurate results, Lunatic is the premier UV/Vis spectrophotometer for protein quantification.

Accuracy users can show off

Lunatic for low-volume UV/Vis analysis

Image Credit: Unchained Labs

Lunatic demonstrates impressive accuracy, which can be verified at any time. Using Fundamentals tryptophan standards, the instrument's accuracy, precision, and linearity can be confirmed at the protein-relevant 280 nm wavelength and an OD range of 20–225. This provides confidence in every sample with data that leaves no room for doubt.

Ready for downstream use

UV/Vis performance verification report

Image Credit: Unchained Labs

Lunatic meets USP and Ph. Eur. UV/Vis requirements for absorbance accuracy, precision, linearity, wavelength accuracy, stray light, and resolution. Performance verification measurements using independently certified NIST standards confirm this compliance. Lunatic is prepared for validation and integration into QC workflows.

Put it on lockdown

Lunatic software offers a comprehensive audit trail

Image Credit: Unchained Labs

For GLP laboratories, Lunatic's software provides 21 CFR Part 11-compliant features, including password protection, electronic signatures, and a comprehensive audit trail.

Dig up genomics' dirt

Lunatic for low-volume UV/Vis analysis

Image Credit: Unchained Labs

Analysis of DNA and RNA samples can be complex. Lunatic's analysis software identifies impurities that traditional A260 measurements might misinterpret as DNA or RNA. This allows for precise quantification of RNA, turbidity, beads, and other factors affecting nucleic acid measurements. This approach eliminates time-consuming, dye-based preparation and provides immediate confirmation of sample suitability.

Set it and forget it

Automated sample loading

Image Credit: Unchained Labs

Lunatic integrates with robotic systems. Connection to any liquid handler system enables completely automated measurements through API setup, preserving precious sample volume for subsequent workflow steps.

Tech

UV/Vis spectrophotometry

What it does

The absorption of light in the UV and visible (UV/Vis) spectrum directly corresponds to the concentration of proteins, peptides, nucleic acids, and other small molecules.

Why it matters

UV/Vis provides swift measurement of nucleic acid and protein concentrations, with analysis benefiting from powerful Unmix deconvolution algorithms. Unmix can resolve the absorbance from different molecules, enabling their separate quantification, such as distinguishing between protein and DNA, or an antibody and its conjugated drug.

Specifications

Source: Unchained Labs

Lunatic instrument specifications
Dimensions 37 cm W x 46 cm D x 33 cm H; 21 kg
Operating voltage 24 VDC, 30 W (max)
Connection USB, TCP/IP (Service, SiLA)
Light source Xenon flash lamp
Detectors UV/Vis polychromatic spectrophotometer
Approval CE, FCC, CSA
Wavelength range 230–750 nm
Wavelength accuracy ≤400 nm: ±1 nm; ≥400 nm: ±2 nm
Spectral resolution Better than 2 nm (toluene in hexane)
Absorbance precision (1 cm quartz cuvette) <1 OD: ±0.005 OD st dev 1–2 OD: ±0.5% CV
Absorbance accuracy (1 cm quartz cuvette) <1 OD: ±0.01 OD 1–2 OD: ±1%

Source: Unchained Labs

Lunatic plate specifications High Lunatic Plate Lunatic Plate
Application area High concentration samples, typically proteins Low concentration samples, typically nucleic acids
Sample retention time Up to two hours Up to two hours
Recommended sample volume 2 µL 2 µL
Pathlength(s) 0.1 mm & 0.7 mm path 0.5 mm path
Measurement time for full plate ~10 minutes ~five minutes
Measurement range:
OD 10 mm
ng/µL dsDNA
mg/mL ave protein mix

0.03–275 OD 10 mm
1.5–13750 ng/µL
0.03–275 mg/mL

0.03–40 OD 10 mm
1.5–2000 ng/µL
0.03–40 mg/mL
Absorbance precision (10 mm pathlength) <1 OD: ±0.01 OD st dev
1–200 OD: ±1% CV
<1 OD: ±0.01 OD st dev
>1 OD: ±1.5% CV
Absorbance accuracy (10 mm pathlength) <1 OD: ±0.02 OD
1–200 OD: ±2%
<1 OD: ±0.02 OD
>1 OD: ±4%
Dimensions 8.55 cm W x 12.8 cm D x 1.21 cm H
Samples per plate 96 (12 x eight microplate format)

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.