Ptychography in Life Sciences

NewsGuard 100/100 Score

Cell imaging techniques often rely on the use of dyes or genetic engineering to introduce fluorescent proteins.

Although it enhances contrast in the images, they can interfere with cellular activities. It can be hard to know whether these manipulations cause any fluctuations from the normal cell behavior. Ptychography presents a recently developed non-invasive method to study cells and cell cultures without the use of labels or artefacts.

Phasefocus Virtual Lens® is a novel method for high fidelity quantitative imaging and microscopy.  It is known in the scientific literature as
Phasefocus Virtual Lens® is a novel method for high fidelity quantitative imaging and microscopy. It is known in the scientific literature as "ptychography". Image Credit: Phasefocus

Method

There is an illumination beam shining on the specimen, behind which a camera is placed. Both the specimen and the illumination beam are moved in proportion to one another. This result in a series of partly overlapping illuminated areas on the specimen. The pattern of light diffracted by the specimen for each illuminated area is caught by a camera which is a charge-coupled device (CCD) camera. CCD facilitates conversion from pixels to digits or vice versa. The diffraction pattern image is further processed using a ptychography algorithm.

Phasefocus Virtual Lens

Advantages of Ptychography

Ideal for transparent samples

The diffraction pattern emerges from light has passed through the specimen, and this occurs with high accuracy and contrast. This makes it ideal for structural studies of nearly transparent cells. Ptychography is also less constrained in image resolution – the resolution is only limited by the effective numerical aperture (range of angles from which light can be detected by the lens) of the detector.

3D analysis

The image formation is not done by the detecting lens itself, but by the ptychography algorithm. An example of one such algorithm is the extended ptychography iterative engine (ePIE). ePIE algorithms produce two images: one of the amount of light that has been absorbed by the specimen and one of the amount of phase delay introduced to the illumination as it passes through the specimen. The depth of the images can be decided after acquisition. This is highly beneficial for 3D analysis of specimens and more complex cell cultures, a field which is continuously being developed.

Not restricted by optics of the system

ePIE also conducts calculations of the complex waveform of the illumination. Calculating the waveform allows for high quality reconstruction even when the illumination form is not known. This also avoids restrictions arising due to the optical system and places more emphasis on the algorithm. Several developments are therefore focusing on improving and extending the algorithm.

Life Sciences Applications

Increased brightness

Cells in the A549 cell line were analyzed using ptychography and compared to another microscopy technique called DIC (Diffrential Interference Contrast). The ptychography imaging  is more similar to fluorescent imaging. It does not have a halo around the cells, as seen with other techniques. The areas inside the cells have brighter pixels than those outside the cell, making distinction easy. The nucleus can also be seen as the brightest point in the cell, a distinction which is harder to make with DIC microscopy.

Increased contrast

Certain cells had higher contrast than other in the study mentioned before. The authors hypothesize that this could be due to those cells entering the G2/M phase prior to mitosis. The main advantage of ptychography has been its ability to show distinctions between cells in different stages of the cell cycle. Other non-invasive or label-free imaging techniques have struggled with this. In addition, the full cell cycle of a A549 cell takes 18 hours. Ptychography was performed every five minutes for 20 hours, giving images of the full cell cycle for many cells. This allowed researchers to track and identify the changes happening.

Applications in Bacterial Imaging

Ptychography has also been applied to bacteria, without the need to isolate the samples. Deinococcus radiodurans has been in focus for its high tolerance towards ionizing radiation and possible correlations to its nucleoid structure.

Electron microscopy techniques applied have yielded contradicting results. Using ptychography, researchers found four distinct subunits present inside the bacteria which they identified as nucleoids owing to their general size and shape. The authors therefore believe ptychography can be used as a viable method to analyze bacterial nucleoids, independent of electron microscopy.

Further Reading

Last Updated: Aug 23, 2018

Sara Ryding

Written by

Sara Ryding

Sara is a passionate life sciences writer who specializes in zoology and ornithology. She is currently completing a Ph.D. at Deakin University in Australia which focuses on how the beaks of birds change with global warming.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Ryding, Sara. (2018, August 23). Ptychography in Life Sciences. News-Medical. Retrieved on April 24, 2024 from https://www.news-medical.net/life-sciences/Ptychography-in-Life-Sciences.aspx.

  • MLA

    Ryding, Sara. "Ptychography in Life Sciences". News-Medical. 24 April 2024. <https://www.news-medical.net/life-sciences/Ptychography-in-Life-Sciences.aspx>.

  • Chicago

    Ryding, Sara. "Ptychography in Life Sciences". News-Medical. https://www.news-medical.net/life-sciences/Ptychography-in-Life-Sciences.aspx. (accessed April 24, 2024).

  • Harvard

    Ryding, Sara. 2018. Ptychography in Life Sciences. News-Medical, viewed 24 April 2024, https://www.news-medical.net/life-sciences/Ptychography-in-Life-Sciences.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.