Miniaturized brush tested as a possible technique for loosening cells from walls of pancreatic cysts

NewsGuard 100/100 Score

In a potential step forward for early pancreatic cancer diagnosis, a miniaturized brush was successfully tested as a possible technique for loosening cells from the walls of pancreatic cysts. If proven safe to use, the technique could dramatically increase the number of cystic cells available for analysis, a key advance given the scarcity of cells in cystic fluid drawn with a needle alone.

Researchers at Sweden's KTH Royal Institute of Technology proposed modifying endoscopicultrasound-guided fine needle aspiration with the addition of a loop brush which can be inserted into a cyst through the needle, says Wouter van der Wijngaart, professor of Micro and Nanosystems at KTH.

In order to detect malignancy in a pancreatic cyst, the cells from the inner wall of the cyst need to be analyzed. You may find some of those released into the cystic fluid naturally; but sometimes you find none - that is why we try to brush them off."

Wouter van der Wijngaart, Professor of Micro and Nanosystems, KTH

Pancreatic cancer is the fourth leading cause of cancer death in Western countries. With a survival rate of between 2 and 9 percent, early detection is critical.

"Pancreatic cystic lesions are precursors of pancreatic cancers and a prime target for early diagnosis," van der Wijngaart says. However, he says, 20 percent of cystic fluid samples contain negligible amounts of cells, or no cells at all, hampering a proper diagnosis.

To evaluate the functionality of the device, the researchers performed tests on models of cysts and intestines from pigs and cows. They fitted the aspiration needle with a 50 micrometer-thin nitinol wire shaped in a 1 cm diameter loop, which is fixated to a 280 micrometer-thick nitinol guidewire. The loop is compressed and inserted into a cyst through a fine needle with a diameter less than 0.5 mm.

Once inside the cyst, the brush opens up and is rotated with low force to abrade the cells from the cyst wall. Then the loop is retracted and the cystic fluid is aspirated through the needle and collected for cytology.

The cell content increased up to 54 times when using low‐viscous water as fluid in soft tissue, soft‐like cavities; up to 174 times when using high‐viscous glycerol; and at least 10 times in cow ovary cysts.

The project was initiated by co-author Francisco Baldaque Silva, surgeon at Karolinska University Hospital, and the experimental work was performed by PhD student Filipe Marques. Also contributing to the study were KTH researcher Niclas Roxhed and Urban Arnelo, a researcher at Karolinska Institutet. The project was sponsored by Region Stockholm.

Source:
Journal reference:

Marques, F., et al. (2020) A loop‐shaped minimally invasive brush for improved cytology sampling of pancreatic cysts during EUS‐FNA. Medical Devices & Sensors. doi.org/10.1002/mds3.10165.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
First FDA-approved cellular therapy for metastatic melanoma available in South Florida