The Avanti® J-26S centrifuge series is the only high-performance system you’ll ever need. Experience simplified high-throughput sample processing and more control with powerful features including low heat output, imbalance tolerance and quiet performance.

  • Easy to operate
  • Built-in safety features
  • Application versatility

Features

Application Versatility

  • Process six liters of fermentor output in less than 10 minutes
  • Deliver a subcellular fraction at 82,000 x g
  • Run 24 microplates at a time
  • Separate live cell populations with elutriation

Complete BioSafety* systems for ultimate peace of mind

  • BioCertified** rotors, instruments and labware with microbiological aerosols
  • Sterile filters prevent discharge of infectious materials

Dual-System Rotor Recognition for operator safety

  • Automatically detect which rotor is installed
  • Prevent rotors from running above maximum-rated speeds while maintaining the run  
  • Friction Reduction System for faster, quieter and more energy-efficient runs
  • Lightweight J-Lite Rotors for reduced run times and high g-force
  • Ergonomic Earth-Friendly Design
  • Optimal working surface height for easier loading and unloading of rotors
  • Each instrument saves approximately 9.6 pounds of post-consumer materials from the landfill

Avanti J-26S XP and J-26S XPI Features Overview

Feature

Avanti J-26S XPI

Avanti J-26S XP

User-defined programs

30 two-step pre-written programs  

NONE

Time settings

1 min – 99+ hours; Hold

1-180 mins; Hold

Acceleration rates

12 plus max

2 plus max

Deceleration rates

3 plus max

3 plus max

Simultaneous display of set and operative parameters  

YES

NONE

Delayed start

YES

NONE

Continuous flow;  Zonal; Elutriation capability

YES

NONE

Key lock-out

YES

NONE

 

Instrument Specifications

Avanti J-26S Centrifuge System Specifications

UNSPSC

41103905

Height

86 cm (34 in); with door open 149 cm (58.5 in)

Width

71 cm (28 in)

Depth

86 cm (34 in); 102 cm (40.25 in) (including air diverter extending from back panel)

Weight

290 kg (640 lbs)

Friction Reduction System (FRS)

Mechanical rotary vane pump reduces chamber pressure to 0.25 ATM (190 mm [7.5 in] Hg)

Max capacity volume range

6 Liters

Max speed

26,000 rpm

Noise level (0.91meters /3' in front of centrifuge)

57 dBA

Max heat dissipation into room (steady-state conditions)

2.0 kW (6,900 BTU/hr)

Rotor ID

Automatic

Set temperature

-10° C to +40° C (in 1° C increments)

Set time

1 Min - 3 Hours, Continuous Hold

Refrigeration system

Non-CFC, non-ozone depleting refrigerant

Speed control

± 10 rpm of set speed or 0.1%, whichever is greater

Speed range

100 to 26,000 rpm or equivalent RCF; 0 to 5,000 rpm for elutriation

Temperature control

± 2° C of set temperature (after equilibration)

Zonal capability

Yes

Single tube sample volume range

1.8 - 1,000 mL

Ambient temperature range

16° C to 38° C

Clearances required

7.6 cm (3.0 in) sides; 16.0 cm (6.25 in) rear

Door

6.1 cm (2.4 in) thick plastic resin with steel plate

Humidity restrictions

< 95% (noncondensing)

Pollution degree

2

Rotor chamber diameter

51.3 cm (20 in)

Time–actual display

Indicates run time remaining (timed run) or elapsed time (hold run)

Maximum force at r max (g)

82,000 x g

Accelertion

Maximum, Slow

Deceleration

Maximum, Slow, Off

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.