Advantages and Applications of Bruker’s MRI CryoProbe Series

The MRI CryoProbe series from Bruker has superior resolution and provides the ultimate image with unmatched performance. MRI CryoProbes are equipped with very low temperatures, closed-cycle cooled RF-coils and preamplifiers, delivering an increased signal-to-noise ratio (SNR) by a factor of 2.5 in routine in vivo MRI applications at 9.4 T when compared to standard room temperature 1H RF-coils.

MRI Cyroprobe.

MRI Cyroprobe.

Pioneering performance

Bruker is recognized as the principal innovator in magnetic resonance and originally launched the CryoProbe technology more than a decade ago. Today, the company has installed over 1200 CryoProbes all across the globe, providing unrivaled performance by reliably achieving increased SNR. This increased sensitivity results in shorter measurement times and improved throughput with reduced animal stress.

Unique technology for excellent results

Cryogenically cooled RF-coils and preamplifiers are used in Bruker’s MRl CryoProbe technology. A closed-cycle refrigeration system is used to cool these RF-coils and preamplifiers, thereby improving the coil performance and significantly reducing the noise contribution of the associated electronics.

The MRl CryoProbe handles and supervises animals in a very similar manner to that of standard room temperature RF-coils. Cooling the MRI CryoProbe can be achieved outside the magnet, allowing the scanner time to be used optimally.

MRI CryoCoils are advantageous in many ways over standard room-temperature RF-coils:

  • Higher resolution in vivo up to 20 µm
  • Increase in SNR by up to a factor of 5
  • Shorter durations of anesthesia
  • Shorter measurement times
  • Shorter measurements directly enable higher productivity and lower costs per sample
  • New applications cannot be accessed with room temperature RF-coils (high resolution, fMRI, etc.)

Applications

Dynamic 13C-MRS of the mouse brain

Localized 13C(1H} spectroscopy (ISIS) over time of mouse brain after orally administrated [1-13Cl] glucose.

Localized 13C(1H} spectroscopy (ISIS) over time of mouse brain after orally administrated [1-13Cl] glucose. Courtesy: H. Terasawa, Kumamoto University, Kumamoto, Japan.

Phantom measurements reveal an increase in SNR in 13C by more than a factor of 5 at 9.4 T.

Comparison of 1H four channel phased array receive-only MRI CryoProbe with room temperature phased-array coil

The significant signal gain reduces the scan time considerably without compromising the resolution. The four channel phased array MRI CryoProbe (left image) can achieve a signal-to-noise gain of 2.6 compared to a room temperature four channel phased array coil (right image).

Comparison of 1H four channel phased array receive-only MRI CryoProbe with room temperature phased-array coil.

Comparison of 1H four channel phased array receive-only MRI CryoProbe with room temperature phased-array coil.

Mouse coronary artery imaging

Maximum intensity projection of a full mouse cardiac cycle allows for in vivo visualization of the coronary arteries of a mouse heart.

Mouse Coronary Artery lmaging.

Mouse Coronary Artery lmaging.

1H MRS in mouse Hippocampus: 2.7µl voxel in vivo

Localized 1H spectroscopy in mouse brain at 11.7 T in a 2.7µl voxel

Localized 1H spectroscopy in mouse brain at 11.7 T in a 2.7µl voxel. Courtesy: M. Santin, R. Paquin et al., ICrv1-CENIR, Paris, France.

Mouse spine imaging

The below picture shows high-resolution (46 x 46 µm in-plane) mouse spine imaging acquired using TurboRARE, captured in less than 7 minutes at 9.4 T, clearly differentiating white and gray matter and revealing fine anatomical details, such as cerebrospinal fluid, vessels, and root ganglions.

Mouse Spine lmaging

Mouse Spine lmaging

The MRI CryoProbe family

1H four channel phased array receive-only MRI CryoProbe for 12 cm gradients and larger

The enormous signal gain helps to achieve a drastic reduction in scan time while maintaining a very high resolution. Using this MRI CryoProbe, a signal-to-noise-gain of 2.6 can be achieved when compared to a room temperature, 8 four channel phased array coil.

Bruker also offers four channel phased array coils at 7 T, 9.4 T and 11.7 T and can develop the four channel phased array coils at 4.7 T based upon request.

1H quadrature transmit/receive MRI CryoProbe for 6 cm gradients

This MRI CryoProbe is specially designed for the 11 cm mouse scanners and can also be employed in all BioSpec with a 6 cm gradient insert. Bruker also supplies this MRI CryoProbe as a commercial product at 11.7 T and 15.2 T.

X-nuclei MRI CryoProbe with combined 1H room temperature RF-coil

Lower NMR frequencies offer a number of signal-to-noise gain benefits. The SNR gain will be more for the nuclei if their frequency is low. Hence, signal-to-noise gains of a factor of 5 can be achieved in 13C measurements.

Bruker supplies this MRI CryoProbe as a commercial product at 7 T and 9.4 T and can develop other frequencies upon request.

DTI fibers

Brain connectivity studies are difficult to perform in small animals but can be achieved using sophisticated MRI technologies, such as a 7T BioSpec and MRI CryoProbe technology for image acquisition. The below picture shows high-resolution DT-MRI and fiber tracking of the live mouse brain, detailing the features of the fine cytoarchitecture of the nervous tissue and delineating the fiber tracts organization.

DTI fibers of the live mouse brain.

DTI fibers of the live mouse brain. Courtesy: L.-A. Harsan, D. von Elverfeldt et al., University Medical Center Freiburg, Freiburg, Germany.

Unmatched Results

ln vivo mouse brain with 19.5 µm resolution at 15.2 Tesla

Comparison of micro-structures in the mouse brain measured at 15.2 T by using high resolution SWI with histological Nissle staining (below}.

Comparison of micro-structures in the mouse brain measured at 15.2 T by using high resolution SWI with histological Nissle staining (below}.

Angiography

Time-of-flight angiography with no contrast agent at high spatial resolution showing excellent contrast enabling the identification of fine vascular structures

Time-of-flight angiography with no contrast agent at high spatial resolution showing excellent contrast enabling the identification of fine vascular structures

Testimonials

"This increased SNR can be invested in either reducing the acquisition time by a factor 6.25 at constant SNR or, as in the examples shown, in enhancing image quality, i.e. increase the CNR to improve the definition of anatomical structures. and/or to increase the spatial resolution in structural imaging ad angiography.”

Prof. Dr. Markus Rudin, ETH. Zürich. Switzerland

"ln conclusion, cardiac morphology, cardiac chamber quantification and cardiac function assessment using a cryogenically-cooled RF probe is feasible and affords SNR gains in the range of 3.0 to 5.0 compared to a conventional room temperature cardiac RF coil set-up.”

Prof. Dr. Thoralf Niendorf, MDC, Berlin, Germany

About Bruker BioSpin - NMR, EPR and Imaging

Bruker BioSpin offers the world's most comprehensive range of NMR and EPR spectroscopy and preclinical research tools. Bruker BioSpin develops, manufactures and supplies technology to research establishments, commercial enterprises and multi-national corporations across countless industries and fields of expertise.


Sponsored Content Policy: News-Medical.net publishes articles and related content that may be derived from sources where we have existing commercial relationships, provided such content adds value to the core editorial ethos of News-Medical.Net which is to educate and inform site visitors interested in medical research, science, medical devices and treatments.

Last updated: Mar 11, 2022 at 12:19 AM

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Bruker BioSpin - NMR, EPR and Imaging. (2022, March 11). Advantages and Applications of Bruker’s MRI CryoProbe Series. News-Medical. Retrieved on April 16, 2024 from https://www.news-medical.net/whitepaper/20170728/Advantages-and-Applications-of-Brukers-MRI-CryoProbe-Series.aspx.

  • MLA

    Bruker BioSpin - NMR, EPR and Imaging. "Advantages and Applications of Bruker’s MRI CryoProbe Series". News-Medical. 16 April 2024. <https://www.news-medical.net/whitepaper/20170728/Advantages-and-Applications-of-Brukers-MRI-CryoProbe-Series.aspx>.

  • Chicago

    Bruker BioSpin - NMR, EPR and Imaging. "Advantages and Applications of Bruker’s MRI CryoProbe Series". News-Medical. https://www.news-medical.net/whitepaper/20170728/Advantages-and-Applications-of-Brukers-MRI-CryoProbe-Series.aspx. (accessed April 16, 2024).

  • Harvard

    Bruker BioSpin - NMR, EPR and Imaging. 2022. Advantages and Applications of Bruker’s MRI CryoProbe Series. News-Medical, viewed 16 April 2024, https://www.news-medical.net/whitepaper/20170728/Advantages-and-Applications-of-Brukers-MRI-CryoProbe-Series.aspx.

Other White Papers by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.