RT-LAMP assay shows promise as point-of-care SARS-CoV-2 detection assay across multiple settings

NewsGuard 100/100 Score

In a recent study published on the medRxiv* preprint server, researchers evaluate the feasibility and robustness of an optimized reverse transcription loop-mediated isothermal amplification (RT-LAMP) severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection assay across multiple resource-restricted settings.

Study: Multicenter international assessment of a SARS-CoV-2 RT-LAMP test for point of care clinical application. Image Credit: kittirat roekburi / Shutterstock.com

This news article was a review of a preliminary scientific report that had not undergone peer-review at the time of publication. Since its initial publication, the scientific report has now been peer reviewed and accepted for publication in a Scientific Journal. Links to the preliminary and peer-reviewed reports are available in the Sources section at the bottom of this article. View Sources

SARS-CoV-2 screening approaches

SARS-CoV-2 tests that allow for rapid screening in low/medium resource non-medical settings remain vital amid continued coronavirus disease 2019 (COVID-19) waves, the emergence of new variants, and limited vaccine deployment to mitigate and suppress the spread of SARS-CoV-2.

Currently used quantitative real-time polymerase chain reaction (qRT-PCR) assays have sensitive analytical limits of detection (LoD). However, this technique requires sophisticated settings and is associated with a long turnaround time of up to two to three days to obtain final results.

Where point-of-care (PoC) applications are restricted by infrastructure and time, such as during traveling, reducing the barriers to testing is urgently needed. Further, in high-risk environments, as routine testing reduces the risk of COVID-19 outbreaks, screening may need to be conducted as frequently as twice weekly. Overall, effective COVID-19 containment demands PoC tests with a shorter turnaround time and high accessibility.

In the past, RT-LAMP has been used to diagnose several viral diseases, including those caused by SARS and the Middle East Respiratory Syndrome (MERS). Among its many advantages, RT-LAMP can be executed in a low-resource setting by merely heating the test samples and reagents in a reaction tube and producing the results within 30 minutes.

Although recent studies have used RT-LAMP directly on patient samples without any ribonucleic acid (RNA) purification, the feasibility of this approach is unknown. More importantly, the robustness of this diagnostic method needs to be tested, particularly in countries lacking infrastructure and resources where even reagent availability could be limited.

About the study

In the current study, researchers optimized a commercially available RT-LAMP kit using systematic primers and further improved the test’s sensitivity using primer multiplexing and several additives. This method was then tested on raw SARS-CoV-2 RNA samples using a PoC instrument FluorPLUM, which demonstrated the de-centralized deployment of the RT-LAMP assay.

The researchers sequentially screened six primer sets for SARS-CoV-2, including gene envelope 1 (E1), gene nucleocapsid (N2), open reading frame 1a (ORF1a), and one for human actin beta (ACTB). Several different 'TTTT' linker formats over a wide range of concentrations using only 30 copies of synthetic SARS-CoV-2 target RNA were also used.

RT-LAMP reactions were conducted at 65°C in a thermocycler and the time to result (TTR) (in minutes) was tracked. TTR was defined as the point at which the relative fluorescence units (RFU) curve crossed the fluorescent threshold of the used green fluorescent dye.

Finally, the researchers plotted TTR values against sensitivity, as defined as the percentage of confirmed positives over positives tested, and specificity, which was defined as the percentage of confirmed negatives over negative controls tested.

Study findings

While variability in performance and ideal concentrations across different primer sets undermined the value of the optimization matrix, multiplexing and supplementing reactions with 40 mM guanidine hydrochloride (GuHCl) and 0.5M betaine improved RT-LAMP sensitivity.

The resultant optimized RT-LAMP yielded 20 copies of SARS-CoV-2 viral RNA per reaction, which was associated with an improved LoD with diagnostic significance. Notably, a ten-fold increase in the LoD of a COVID-19 viral diagnostic test also increases the false negative rate by 13%. However, the test-used primer sets showed no mismatches when mapped onto genomic sequences of the SARS-CoV-2 Delta and Omicron variants of concern.

Further, by targeting different regions of the SARS-CoV-2 genome, this test fulfilled the United States Food and Drug Administration (FDA) criteria for molecular tests that require detection of more than one viral genome region.

The FDA-approved BGI RT-qPCR kit is a diagnostic RT-PCR test that diagnoses a sample with cycle threshold (Ct) of less than 37 as SARS-CoV-2-positive. When RT-LAMP was used to extract RNA from nasopharyngeal (NP) samples, this method successfully detected SARS-CoV-2 RNA in all positives except three with 36 < Ct < 37. Further, this assay provided results within less than 20 minutes, which is comparable to the two hours required to complete RT-qPCR.

When evaluated at the health centers of Ecuador, RT-LAMP, due to differences in reagent sources and sample handling, took about 40 minutes to yield results. The receiver operating characteristic (ROC) curve analysis showed an area under the curve (AUC) value of one and 100% sensitivity and specificity, thus indicating the significance of optimizing the cutoff TTR based on different testing conditions. At 41 minutes of cutoff TTR, the assay exhibited 100% sensitivity and 100% specificity.

When deployed in a portable “lab-in-a-box,” the RT-LAMP prototype assay provided combined incubation, optical monitoring, and graphing. Direct RT-LAMP with the FluorPLUM device detected viral loads beyond 7.9 X 106 copies/mL with high sensitivity and were comparable to results obtained with thermocyclers. In the future, this prototype, specifically FluoroPLUM, needs to be broadly field-tested to establish its robustness as a PoC device.

Conclusions

The optimized rapid RT-LAMP assay used in the study yielded accurate results similar to the FDA-approved BGI RT-PCR kit. Importantly, this diagnostic technique did not require sophisticated laboratory infrastructure or specialized thermocycling instruments for RNA extraction, nor did it require optical monitoring equipment.

The RT-LAMP assay also detected high viral loads in raw NP samples, positioning itself as a good substitute for laboratory RT-PCR testing. Thus, the current study findings demonstrate the potential of RT-LAMP as a PoC test that could be distributed across sample collection centers to quickly and accurately identify infectious individuals.

With a detection threshold limit of Ct 27, the RT-LAMP assay could provide high-fidelity molecular diagnostics to distributed community testing at a meager cost of about $2.40 U.S. dollars. Overall, this assay could significantly contribute towards public health efforts to mitigate the spread of SARS-CoV-2.

This news article was a review of a preliminary scientific report that had not undergone peer-review at the time of publication. Since its initial publication, the scientific report has now been peer reviewed and accepted for publication in a Scientific Journal. Links to the preliminary and peer-reviewed reports are available in the Sources section at the bottom of this article. View Sources

Journal references:

Article Revisions

  • May 11 2023 - The preprint preliminary research paper that this article was based upon was accepted for publication in a peer-reviewed Scientific Journal. This article was edited accordingly to include a link to the final peer-reviewed paper, now shown in the sources section.
Neha Mathur

Written by

Neha Mathur

Neha is a digital marketing professional based in Gurugram, India. She has a Master’s degree from the University of Rajasthan with a specialization in Biotechnology in 2008. She has experience in pre-clinical research as part of her research project in The Department of Toxicology at the prestigious Central Drug Research Institute (CDRI), Lucknow, India. She also holds a certification in C++ programming.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Mathur, Neha. (2023, May 11). RT-LAMP assay shows promise as point-of-care SARS-CoV-2 detection assay across multiple settings. News-Medical. Retrieved on April 26, 2024 from https://www.news-medical.net/news/20220304/RT-LAMP-assay-shows-promise-as-point-of-care-SARS-CoV-2-detection-assay-across-multiple-settings.aspx.

  • MLA

    Mathur, Neha. "RT-LAMP assay shows promise as point-of-care SARS-CoV-2 detection assay across multiple settings". News-Medical. 26 April 2024. <https://www.news-medical.net/news/20220304/RT-LAMP-assay-shows-promise-as-point-of-care-SARS-CoV-2-detection-assay-across-multiple-settings.aspx>.

  • Chicago

    Mathur, Neha. "RT-LAMP assay shows promise as point-of-care SARS-CoV-2 detection assay across multiple settings". News-Medical. https://www.news-medical.net/news/20220304/RT-LAMP-assay-shows-promise-as-point-of-care-SARS-CoV-2-detection-assay-across-multiple-settings.aspx. (accessed April 26, 2024).

  • Harvard

    Mathur, Neha. 2023. RT-LAMP assay shows promise as point-of-care SARS-CoV-2 detection assay across multiple settings. News-Medical, viewed 26 April 2024, https://www.news-medical.net/news/20220304/RT-LAMP-assay-shows-promise-as-point-of-care-SARS-CoV-2-detection-assay-across-multiple-settings.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
COVID-19 linked to higher dementia risk in older adults, study finds