Study opens new possibilities of tailoring radiopharmaceutical treatment to neuroendocrine cancer patients

NewsGuard 100/100 Score

A simple blood draw can provide physicians with valuable information that can determine if peptide receptor radionuclide therapy (PRRT) is likely to be effective in a patient with neuroendocrine cancer. The blood-based biomarker PPQ can predict which patients will respond to PRRT with 96 percent accuracy; changes in another biomarker, NETest, correctly correlate with PRRT response in 90 percent of patients. The study, published in the April issue of The Journal of Nuclear Medicine, opens new possibilities of tailoring radiopharmaceutical treatment to patients.

While biomarkers have been used to predict the outcomes of treatments for breast, prostate, and other cancers, there are currently no objective means to predict the efficacy of radiopharmaceutical therapy for neuroendocrine tumors. "In previous studies our team introduced the blood-based biomarkers PPQ and NETest as a measure for determining whether treatment with PRRT would be successful," noted Lisa Bodei, MD, PhD, nuclear medicine physician at Memorial Sloan Kettering Cancer Center in New York, New York. "In this new study we sought to validate the role of PPQ and NETest in predicting response and monitoring PRRT."

Sixty-seven patients with somatostatin receptor-positive gastroenteropancreatic and lung neuroendocrine tumors were included in the study. All patients had metastatic disease and had received prior treatments. Blood samples were collected before each cycle of PRRT and at follow-up. PPQ was scored as either positive (likely to respond) or negative (unlikely to respond), and NETest was measured on a scale of zero to 100, with the upper limit of normality being 20.

Of the 67 patients in the study, 40 were classified as PPQ+, and 39 of them (98 percent) responded to PRRT. Twenty-seven patients were PPQ–, and 25 patients in this group experienced disease progression despite PRRT. The overall predictive accuracy of PPQ was 96 percent.

NETest was elevated in all patients prior to PRRT therapy. For PRRT responders, baseline NETest levels were 67, which decreased by 37 percent after treatment. For non-responders, baseline NETest levels were 44, which increased by 76 percent at follow-up. The NETest biomarker was 90 percent accurate for determining PRRT response.

The results of this study demonstrate that not all tumors are created equal; some are more prone to respond to PRRT, and some are less susceptible to radiopharmaceutical therapy. This is the reason why our research is important: to understand from the start which patients will require an intensified treatment plan and which patients, instead, can benefit from a lighter regimen will tremendously improve their management."

Lisa Bodei, MD, PhD, nuclear medicine physician, Memorial Sloan Kettering Cancer Center

This study was made available online in November 2022.

Source:
Journal reference:

Bodei, L., et al. (2022). Interim Analysis of a Prospective Validation of 2 Blood-Based Genomic Assessments (PPQ and NETest) to Determine the Clinical Efficacy of 177Lu-DOTATATE in Neuroendocrine Tumors. Journal of Nuclear Medicine. doi.org/10.2967/jnumed.122.264363.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Revolutionizing diabetes management with reliable blood glucose monitoring without finger pricking