Peer-reviewed study shows six times lower blood damage in Realheart® TAH than market-leading device in vitro

Scandinavian Real Heart AB (publ) announces today that a study sponsored by the company has been published in the peer-reviewed journal Nature Scientific Reports, showing that the Realheart® TAH causes about six times less blood damage (hemolysis) than the only FDA-approved artificial heart device currently in wide clinical use. The study was carried out in a lab-based system mimicking full body circulation. Further, the study shows that the Realheart® TAH preserves a protein essential for blood coagulation and the prevention of internal bleeding.

In the current study, complete devices were tested in a laboratory circuit simulating both systemic circulation and lung circulation and under the test conditions, there was clear difference between the devices. The Realheart® TAH generated about six times less hemolysis than the comparator device (normalized hemolysis index, mgNIH: 35.5 ± 4.3 versus 226.0 ± 30.6 mg/100 L; p = 0.002), with significantly lower blood damage at every measurement point after five minutes. Additionally, the comparator produced significantly higher levels of cell fragments – debris from damaged blood cells – whereas no corresponding increase was observed with the Realheart® TAH.

The study also evaluated the function of the coagulation protein von Willebrand factor, which is typically damaged in patients with continuous flow heart pumps leading to increased risk of the bleeding disorder acquired von Willebrand syndrome. Both pulsatile artificial hearts fully preserved von Willebrand factor function, in contrast to a continuous-flow blood pump used as reference (p = 0.023 for both pulsatile devices). The findings confirm a fundamental advantage of the pulsatile operating principle on which the Realheart® TAH is built, and are believed to be an indicator of a lower risk of device-related bleeding complications.

When we published our first head-to-head study on human blood in April, we communicated that more comprehensive full-body circulation testing would follow. We added lung circulation to the model and have now delivered on that step – and under these more clinically relevant conditions, the difference grew to more than six-fold in favor of the Realheart® TAH. Together with the preserved function of von Willebrand factor, an important indicator of bleeding risk, these results further strengthen the safety documentation we are building ahead of the clinical evaluation of our artificial heart.”

Ina Laura Perkins, CEO, Realheart

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Why keto appears to lower blood pressure for some people but not others