Could anterior nasal swabs be an effective alternative for SARS-CoV-2 testing?

NewsGuard 100/100 Score

Antigen-detecting rapid diagnostic tests (Ag-RDTs) play a significant role in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) testing. Most Ag-RDTs currently used require nasopharyngeal swab samples. However, collecting nasopharyngeal swab samples requires qualified healthcare professionals, limiting the possibility to scaling up testing. The collection of nasopharyngeal swabs also causes discomfort for patients.

This news article was a review of a preliminary scientific report that had not undergone peer-review at the time of publication. Since its initial publication, the scientific report has now been peer reviewed and accepted for publication in a Scientific Journal. Links to the preliminary and peer-reviewed reports are available in the Sources section at the bottom of this article. View Sources

A diagnostic accuracy study comparing professional-collected anterior nasal and nasopharyngeal swabs

A team of researchers from various institutions in Germany and Switzerland recently performed a prospective diagnostic accuracy study, in which they compared professional-collected anterior nasal swabs to nasopharyngeal swabs, using WHO-listed SARS-CoV-2 Ag-RDT (STANDARD Q COVID-19 Ag Test, SD Biosensor) test kits. The findings of their study have been published on the preprint server, medRxiv.*

In this manufacturer-independent study, individuals who attended the ambulatory SARS-CoV-2 testing facility of Charité University Hospital Berlin, Germany, and were deemed to be at high risk of contracting COVID-19 infection, were enrolled between 11 and 18 November, 2020.

RT-PCR tests of a combined oro-/nasopharyngeal swab sample were used as the reference standard. The sensitivity and specificity of the tests to the different swabs and the percent of positive and negative agreement were assessed during the study. There were a total of 179 participants with an average age of 36.2 years. 48% of the participants were female and 14.5% of the participants had comorbidities.

“The study was continued until 30 positive NP swab samples according to Ag-RDT were obtained, which is the minimum recommended by the WHO Emergency Use Listing Procedure to demonstrate sample type equivalency.”

Results show over 90% agreement in positive and negative tests with both sampling techniques

The results showed that 41 (22.9%) tested positive for SARS-CoV-2 by real-time polymerase chain reaction reverse transcription reaction (RT-PCR). The positive percent agreement of the 2 different sampling techniques in the Ag-RDT was 93.5%. The negative percent agreement between the 2 techniques was 95.9%. The Ag-RDT with anterior nasal sampling had a sensitivity of 80.5% with 33 out of the 41 RT-PCR positives detected and had a specificity of 98.6% compared to that of RT-PCR.

No invalid results were observed in Ag-RDT in either anterior nasal or nasopharyngeal samples. Four patients tested positive by anterior nasal sampling, but not by nasopharyngeal sampling. One patient tested positive by nasopharyngeal sampling only.

The sensitivity with nasopharyngeal sampling was 73.2%, with 30 out of the 41 PCR positives detected, and the specificity was 99.3% compared to RT-PCR. In patients with a high viral load that is greater >7.0 log10 RNA SARS-CoV-2/swab, the sensitivity of the Ag-RDT with anterior nasal sampling was 100% and that for nasopharyngeal sampling was 94.7%.

“The strengths of the study are the standardized sampling methods, two independent blinded readers and an additional semi-quantitative assessment of Ag-RDT results.”

Anterior nasal samples show promise in reducing discomfort to patients and scaling up testing

This study attempts to demonstrate that the sensitivity of a WHO-listed SARS-CoV-2 Ag-RDT using a professional anterior nasal sampling kit is at least the same as that of the nasopharyngeal sampling kit. Interestingly, the differences in the IFUs of the 2 different test procedures could have resulted in different sensitivities.

Based on the results, the authors concluded that anterior nasal samples could be collected with less training, and the patient discomfort with this sampling method is relatively less. It therefore shows potential as a form of antigen testing strategy that can be rapidly and effectively scaled up. More studies of patient self-sampling are needed, however, to facilitate the scaling up of Ag-RDT testing.

“In conclusion, this study demonstrates that sensitivity of a WHO-listed SARS-CoV-2 Ag-RDT using professional AN-sampling kit is at least equal to that of NP-sampling kit, although confidence intervals overlap.”

This news article was a review of a preliminary scientific report that had not undergone peer-review at the time of publication. Since its initial publication, the scientific report has now been peer reviewed and accepted for publication in a Scientific Journal. Links to the preliminary and peer-reviewed reports are available in the Sources section at the bottom of this article. View Sources

Journal references:

Article Revisions

  • Apr 3 2023 - The preprint preliminary research paper that this article was based upon was accepted for publication in a peer-reviewed Scientific Journal. This article was edited accordingly to include a link to the final peer-reviewed paper, now shown in the sources section.
Susha Cheriyedath

Written by

Susha Cheriyedath

Susha is a scientific communication professional holding a Master's degree in Biochemistry, with expertise in Microbiology, Physiology, Biotechnology, and Nutrition. After a two-year tenure as a lecturer from 2000 to 2002, where she mentored undergraduates studying Biochemistry, she transitioned into editorial roles within scientific publishing. She has accumulated nearly two decades of experience in medical communication, assuming diverse roles in research, writing, editing, and editorial management.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Cheriyedath, Susha. (2023, April 03). Could anterior nasal swabs be an effective alternative for SARS-CoV-2 testing?. News-Medical. Retrieved on May 03, 2024 from https://www.news-medical.net/news/20201210/Could-anterior-nasal-swabs-be-an-effective-alternative-for-SARS-CoV-2-testing.aspx.

  • MLA

    Cheriyedath, Susha. "Could anterior nasal swabs be an effective alternative for SARS-CoV-2 testing?". News-Medical. 03 May 2024. <https://www.news-medical.net/news/20201210/Could-anterior-nasal-swabs-be-an-effective-alternative-for-SARS-CoV-2-testing.aspx>.

  • Chicago

    Cheriyedath, Susha. "Could anterior nasal swabs be an effective alternative for SARS-CoV-2 testing?". News-Medical. https://www.news-medical.net/news/20201210/Could-anterior-nasal-swabs-be-an-effective-alternative-for-SARS-CoV-2-testing.aspx. (accessed May 03, 2024).

  • Harvard

    Cheriyedath, Susha. 2023. Could anterior nasal swabs be an effective alternative for SARS-CoV-2 testing?. News-Medical, viewed 03 May 2024, https://www.news-medical.net/news/20201210/Could-anterior-nasal-swabs-be-an-effective-alternative-for-SARS-CoV-2-testing.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.

You might also like...
Did California's pediatric COVID-19 vaccination program reduce reported cases and hospitalizations?