Advancing plasma lipidomics with dia-PASEF for more accurate biomarker discovery

Lipidomics is a powerful tool for understanding the molecular mechanisms underpinning health and disease. By measuring thousands of lipid species simultaneously, researchers are uncovering new biomarkers that could improve disease prediction, diagnosis, and therapeutic monitoring. However, translating these discoveries into clinical applications depends on accurately identifying and quantifying the remarkable diversity of lipids in biological samples.

Image Credit: Krot_Studio/Shutterstock.com

During a recent webinar, Dr. Hannes Röst, Associate Professor at the University of Toronto, discussed how advances in mass spectrometry, particularly data-independent acquisition coupled with Parallel Accumulation Serial Fragmentation (dia-PASEF), are overcoming many of the longstanding challenges in plasma lipidomics. These innovations are providing researchers with greater confidence in lipid identification, improved analytical sensitivity and a more comprehensive view of the plasma lipidome, opening new opportunities across metabolic disease, cancer research and precision medicine.

Lipidomics reveals disease long before symptoms develop

Although Dr. Röst's background is rooted in proteomics, his research increasingly focuses on understanding how lipid metabolism changes during disease. Lipids play diverse biological roles beyond energy storage, acting as structural components of cell membranes and regulators of numerous signaling pathways. Their complexity also makes them particularly attractive as biomarkers, as subtle changes in lipid composition can reflect early disease processes.

One area where this potential has become especially apparent is gestational diabetes. While blood glucose levels typically return to normal following pregnancy, women who develop gestational diabetes remain at significantly increased risk of progressing to type 2 diabetes later in life. Identifying those individuals most likely to develop the disease presents an important opportunity for earlier intervention.

To investigate this question, Dr. Röst's group analyzed plasma samples collected from approximately 1,000 women enrolled in the SWIFT study. Blood samples were obtained six to nine weeks after delivery, when participants were considered metabolically healthy, and the cohort was then followed for eight years to determine which women subsequently developed type 2 diabetes.

Using conventional MS1-based lipidomics, the researchers identified numerous lipid species associated with future disease progression. Rather than observing changes confined to a single lipid class, alterations were detected across neutral lipids, phospholipids, and sphingolipids, suggesting widespread metabolic remodeling years before clinical diagnosis.

The findings highlighted the remarkable predictive power of lipidomics. Machine learning models trained using lipid profiles alone performed as well as, and in some cases better than, fasting plasma glucose for predicting future type 2 diabetes. When lipid measurements were combined with glucose measurements, predictive performance improved further, demonstrating that the two datasets provide complementary biological information rather than simply measuring the same metabolic processes.

Perhaps most strikingly, these predictions were made using samples collected only weeks after pregnancy, almost eight years before disease onset. The results suggest that plasma lipidomics may identify metabolic trajectories long before traditional clinical markers become apparent, offering the possibility of earlier preventative interventions.

Why traditional lipidomics has its limitations

Despite these encouraging findings, conventional lipidomics approaches also exposed several analytical challenges.

Historically, many lipidomics workflows have relied primarily on MS1 measurements, identifying compounds based on their mass-to-charge ratio and chromatographic retention time. While effective for profiling large numbers of lipids, this approach provides only limited structural information and can struggle to distinguish closely related lipid species.

One of the greatest difficulties arises from isobaric lipids. Different molecules can have nearly identical masses yet possess distinct biological functions, making them difficult or impossible to separate using MS1 data alone. As a result, multiple lipid species may be grouped together, masking important biological differences.

Dr. Röst explained that his group increasingly found themselves dissatisfied with these limitations. Although the biological discoveries were exciting, greater confidence in lipid identification was needed to fully understand the molecular mechanisms driving disease.

Improving analytical sensitivity, expanding lipidome coverage, and obtaining detailed fragmentation information therefore became key priorities as the group searched for new mass spectrometry strategies.

Moving beyond MS1 with dia-PASEF

These challenges led the laboratory towards dia-PASEF, a data-independent acquisition strategy implemented on trapped ion mobility spectrometry (TIMS) instruments.

Unlike traditional acquisition methods, dia-PASEF combines ion mobility separation with high-speed fragmentation, enabling substantially more comprehensive collection of tandem mass spectrometry data without sacrificing analytical sensitivity.

Rather than relying solely on precursor ion measurements, researchers obtain detailed fragment ion spectra for virtually every detectable lipid. These additional structural data greatly increase confidence in lipid identification while improving the ability to distinguish closely related lipid species.

The incorporation of ion mobility separation adds another analytical dimension by separating ions according to their size, shape, and mass-to-charge ratio. This helps resolve many species that previously overlapped during analysis, allowing researchers to characterize the plasma lipidome with considerably greater detail.

For lipidomics, these advances represent a significant step forward. Researchers can move beyond assigning broad lipid classes towards identifying individual molecular species with much higher confidence, providing richer biological information for downstream interpretation.

Improving quantitative lipidomics

While identification remains critical, reproducible quantification is equally important for biomarker discovery.

Clinical studies often involve analyzing hundreds or thousands of patient samples collected over many years. Any analytical variability introduced during data acquisition can reduce statistical power and obscure biologically meaningful changes.

The comprehensive nature of dia-PASEF helps address this issue by consistently sampling fragment ions across all detectable analytes. This improves reproducibility between runs while reducing the missing values that frequently complicate data-dependent acquisition workflows.

For large-scale longitudinal studies such as those investigating diabetes progression, these improvements translate directly into greater confidence when comparing patient populations and identifying robust biomarkers.

More comprehensive datasets also support increasingly sophisticated computational analysis. Machine learning approaches rely on consistent, high-quality quantitative measurements, making improved analytical reproducibility particularly valuable for predictive modeling.

Applications beyond metabolic disease

Although much of Dr. Röst's presentation focused on diabetes research, the implications extend well beyond metabolic disorders.

Altered lipid metabolism has emerged as a hallmark of numerous diseases, including cancer, cardiovascular disease, and inflammatory conditions. Cancer cells, in particular, frequently reprogram lipid synthesis and utilization to support rapid proliferation and tumor growth.

By enabling more detailed characterization of lipid composition, next-generation lipidomics provides researchers with new opportunities to investigate these metabolic adaptations. Improved structural information may help identify disease-specific lipid signatures, reveal previously unrecognized biological pathways, and uncover novel therapeutic targets.

Dr. Röst also highlighted ongoing work applying these approaches to cancer research, reflecting the growing recognition that lipidomics is becoming an increasingly important component of multi-omics investigations.

Rather than studying proteins, metabolites, or lipids in isolation, researchers are increasingly integrating multiple molecular datasets to generate a more complete picture of disease biology. Accurate lipid measurements therefore represent an essential contribution to understanding complex biological systems.

The future of plasma lipidomics

The field of lipidomics has advanced rapidly over the past decade, evolving from relatively simple profiling experiments towards highly detailed structural characterization of thousands of molecular species.

Technologies such as TIMS and dia-PASEF are accelerating this transition by combining greater sensitivity, improved quantitative performance, and higher confidence identifications within a single analytical workflow.

For clinical researchers, these developments could significantly improve biomarker discovery by enabling earlier disease detection and more precise patient stratification. The gestational diabetes study presented by Dr. Röst illustrates how lipidomic signatures may reveal future disease risk years before conventional diagnostic markers become abnormal.

As analytical technologies continue to mature alongside advances in computational biology and machine learning, plasma lipidomics is poised to become an increasingly valuable tool across translational research and precision medicine.

Ultimately, the goal extends beyond measuring larger numbers of lipids. By characterizing the lipidome with greater accuracy and biological depth, researchers hope to better understand disease mechanisms and develop more effective strategies for prediction, prevention, and treatment.

About Bruker Daltonics

Empowering Science – Improving Life

Bruker Daltonics delivers cutting-edge mass spectrometry solutions and workflows that help scientists and industry leaders tackle real-world challenges and make new discoveries. From life sciences and pharmaceutical research to food and contaminant analysis, environmental monitoring, forensics, and industrial quality control, our technologies and instruments provide the precision and reliability you need to make confident decisions.

Our innovative platforms - such as timsTOF, scimaX, neofleX, and DART-TQ - combined with advanced software like SCiLS™ Lab, MetaboScape®, and Biopharma Compass®, transform complex data into actionable insights. Breakthrough innovations like Trapped Ion Mobility Spectrometry (TIMS), Omnitrap®, and dual ionization GC-HRMS are redefining what’s possible in mass spectrometry.

Trusted by leading research institutes, universities, government agencies, and industrial partners worldwide, Bruker Daltonics is committed to driving scientific progress and delivering solutions that matter.

(For Research Use Only. Not for use in clinical diagnostic procedures).


Sponsored Content Policy: News-Medical.net publishes articles and related content that may be derived from sources where we have existing commercial relationships, provided such content adds value to the core editorial ethos of News-Medical.net, which is to educate and inform site visitors interested in medical research, science, medical devices and treatments.

Last updated: Nov 20, 2026 at 9:55 AM

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Bruker Daltonics. (2026, November 20). Advancing plasma lipidomics with dia-PASEF for more accurate biomarker discovery. News-Medical. Retrieved on November 24, 2026 from https://www.news-medical.net/whitepaper/20261120/Advancing-plasma-lipidomics-with-dia-PASEF-for-more-accurate-biomarker-discovery.aspx.

  • MLA

    Bruker Daltonics. "Advancing plasma lipidomics with dia-PASEF for more accurate biomarker discovery". News-Medical. 24 November 2026. <https://www.news-medical.net/whitepaper/20261120/Advancing-plasma-lipidomics-with-dia-PASEF-for-more-accurate-biomarker-discovery.aspx>.

  • Chicago

    Bruker Daltonics. "Advancing plasma lipidomics with dia-PASEF for more accurate biomarker discovery". News-Medical. https://www.news-medical.net/whitepaper/20261120/Advancing-plasma-lipidomics-with-dia-PASEF-for-more-accurate-biomarker-discovery.aspx. (accessed November 24, 2026).

  • Harvard

    Bruker Daltonics. 2026. Advancing plasma lipidomics with dia-PASEF for more accurate biomarker discovery. News-Medical, viewed 24 November 2026, https://www.news-medical.net/whitepaper/20261120/Advancing-plasma-lipidomics-with-dia-PASEF-for-more-accurate-biomarker-discovery.aspx.

Other White Papers by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.